DigitaLinx DL-HDFO Manual del usuario - Página 12

Navegue en línea o descargue pdf Manual del usuario para Extensor DigitaLinx DL-HDFO. DigitaLinx DL-HDFO 13 páginas. Fiber optic extender

DigitaLinx DL-HDFO Manual del usuario
The Digitalinx™ Fiber Optic Extender is designed for years of trouble free
service, please reference the troubleshooting chart below if experiencing
issues with the device.
Symptom
Black Screen
Image Distorted or
Displaying Digital
Articles and Noise
No illumination
Status LED
If you have issues, questions, or require assistance with the use of this
device please contact Liberty Wire and Cable with any of the following
contact points:
Liberty Wire and Cable
11675 Ridgeline Drive
Colorado Springs, CO 80921

Troubleshooting

Solution
1.) Check all AC and DC plugs for Connectivity, Ensure all power
LED's are indicating power is present. Check RJ45 plugs to
ensure connectivity.
2.) Ensure the TX unit is plugged into the source and the RX unit
is plugged into the Display.
3.) Ensure the Status LED is green on both units.
4.) Check the Source and Display to ensure they are operating
properly and powered correctly.
1.) Ensure the resolution is set correctly between source
and display. The resolution must be less then or equal to
UXGA@60HZ.
2.) Reboot the system in the correct sequence shown in the
installation section of the manual.
3.) Power down, disconnect and reconnect the optical
connections and DC power adapters and power back up in
the correct sequence.
1.) Check Polarity of LC Plugs. Visually check fiber color codes to
ensure LC cables were built correctly. A-A, B-B etc.
2.) Power down units and clean Fiber receptacles, LC end faces.
Reconnect and power back up in correct sequence shown in
installation section.
Customer Service
Phone: ( 800) 530-8998 and ask for
Email: S [email protected] and indicate
technical assistance.
in Subject Line "Technical Assistance"
Troubleshooting/Customer Service
1-11