DL-HD70LS Owners Manual

Connecting IR Control

The DL-HD70LS is capable of transmitting bi-directional IR signals through the HDBaseT circuit. The DL-HD70LS
comes with 1 IR receiver (eye) and 1 IR emitter (flasher) so you can control devices from either end of the
extender circuit.
Passing IR Signals:
The DL-HD70LS is capable of passing IR signals between 33 and 55 KHz. To prevent damage to
any of the electronics, the extenders should be powered off while inserting or removing any IR
components. Inserting an IR transmitter into the IR IN port may damage the IR circuit for that
extender.

Source Device Control using IR

Attach the IR emitter to the IR receiver of the source device, insert the TS 3.5 mm plug of the emitter to the IR
OUT port of the DL-HD70LS transmitter. Insert the TS 3.5 mm plug of the IR receiver (eye) to the IR IN port of the
DL-HD70LS receiver. Point the source device IR remote at the display location where the IR receiver is located,
IR signals will now travel through HDBaseT to the DL-HD70LS transmitter side where the IR emitter is attached
to the source device.

Remote Display using IR

Attach the IR emitter to the IR receiver of the display device, insert the TS 3.5 mm plug of the emitter to the IR
OUT port of the DL-HD70LS receiver. Insert the TS 3.5 mm plug of the IR receiver (eye) to the IR IN port of the
DL-HD70LS transmitter. Point the source device IR remote at the source device location where the IR receiver
is located, IR signals will now travel through HDBaseT to the DL-HD70LS receiver side where the IR emitter is
attached to the display device.

Source / Display Control from Control System

To pass 3rd party IR system signals through the DL-HD70LS, such as a control system, connect the TS connector
of the IR-AC coupling cable (purchased separately) to the IR output port of the control system and connect the
TRS connector of the IR-AC cable to the IR IN to either transmitter or receiver of the DL-HD70LS.
To DL-HD7LS
Tx or Rx Extender IR Input
10
Tip: +5V DC
Ring: IR Signal
Sleeve: Ground (GND)
+5V DC Lifted
IR Signal
Ground (GND)
Note: Voltage on Tip from RX may be differnt for non Liberty Devices
Sleeve: Ground (GND)
Tip: IR Signal
To Control system or
IR hub output