SW808HD Rear Panel
Matrix and Peripherals Connection
CD/DVD Player
PC
Control Computer
Matrix System Connections
CD/DVD Player
Projector
TV/HDTV
Receiver
APPENDIX
Matrix Switch Communication Protocol
The RS-232/RS-485 communications are half-duplex with variable byte
count packets. For RS-232, the matrix switch operates as a DCE device
and therefore can be connected using a straight cable to a DTE device
such as a computer. The RS-232 connector is a DB-9 female. For RS-485, a
discrete wiring connector is provided for custom connection to any
RS-485 equipment. For full details on connecting to the matrix switch refer
to the User Manual.
Default Communication Settings – 9600, N, 8, 1
Baud Rate
Parity
Data Bits
Stop Bits
DIP SWITCH DESCRIPTION
SW1-SW5: Machine ID (address)
0=ON, 1=OFF
SW1
SW2
SW3
SW4
SW5
0
0
0
0
0
0
0
0
0
1
~
~
~
~
~
1
1
1
1
1
SW6-SW7: RS-485 TX/RX Terminating Resistor
0=ON, 1=OFF
S
W
6
S
W
7
0
0
Resistor ON
1
1
Resistor OFF
1
0
Invalid
0
1
Invalid
SW8: RS-232/RS-485 Master or RS-485 Slave
0=ON, 1=OFF
S
W
8
0
RS-485 Slave Device
1
RS-232/RS-485 Master
9600
None
8
1
Notes
Address for RS-232/RS-485 Master only
Addresses for Slave devices
N
o
e t
s
N
o
e t
s