4 - ADDITIONAL MATERIAL REQUIRED FOR INSTALLATION (NOT SUPPLIED)
Deoxidized annealed copper tube for refrigerant tubing connecting the units of the system; it has to be insulated with
●
foamed polyethylene (min. thickness 8mm). For tubing dimensions, tubing length and elevation difference limits, see
installation manual of outdoor unit.
PVC pipe for condensate drain pipe (ø int.18mm) in lenght suitable to let the condensate flow into the outside drainage.
●
Anti-freeze oil for flare connections (about 30g).
●
Electric wire: use insulated copper wires of size and length as shown in the paragraph "WIRING DIAGRAMS" (Outdoor
●
unit).
5 - OPERATING LIMITS
■ Cooling Maximum conditions
Outdoor temperature :
Room temperature :
■ Cooling Minimum conditions
Outdoor temperature :
Room temperature :
6 - DIMENSIONS, WEIGHT AND REFRIGERANT CONNECTIONS
A
7 - ACCESSORIES
The following accessories are supplied with the unit:
• Remote control unit.
• Batteries for remote control unit.
• Swivel nuts for pipe connection.
• Insulating tube for piping exiting the unit.
• 4 jumper for PCB configuration (see section "JUMPER")
• Wires for Home automation / wired controller (see section "HOME AUTOMATION KIT"):
- wire "Input Contact" - ON/OFF
- wire "Output Contact" - ALARM
Wired controller (optional - not supplied)
The wired controller (code 387030220) can be purchased separately and can be used to manage the single unit, but
also as a centralized controller.
ATTENTION! If you connect the wired controller, the receiver located inside the unit will be disabled and the wired
controller receiver will be activated, so it will be the latter to communicate with the infrared remote control if necessary.
8 - TOOLS REQUIRED FOR INSTALLATION (NOT SUPPLIED)
1. Standard screwdriver
2. Phillips head screwdriver
3. Knife or wire stripper
4. Tape measure
5. Level
6. Sabre saw or key hole saw
43°C D.B.
32°C D.B. / 23°C W.B.
–15°C D.B.
10°C D.B. / 6°C W.B.
C
B
MODEL
7. Hacksaw
8. Core bits ø 8
9. Hammer
10. Drill
11. Tube cutter
■ Heating Maximum conditions
Outdoor temperature :
Room temperature :
■ Heating Minimum conditions
Outdoor temperature :
Room temperature :
A (mm)
B (mm)
AWIA
889
294
AWIB
1013
307
AWIC
1122
329
12. Tube flaring tool
13. Torque wrench
14. Adjustable wrench
15. Reamer (for reburring)
16. Hex. key
5
24°C D.B. / 18°C W.B.
27°C D.B.
–15°C D.B.
5°C D.B.
MODEL
WEIGHT (kg)
AWIA
11
AWIB
13.5
AWIC
17.5
C (mm) CONNECTIONS
212
1/4" - 3/8"
221
1/4" - 1/2"
247
3/8" - 5/8"