Argo AWICS19 Manual de instrucciones de instalación - Página 10

Navegue en línea o descargue pdf Manual de instrucciones de instalación para Aire acondicionado Argo AWICS19. Argo AWICS19 18 páginas. Split air conditioner system

11- WIRED CONTROLLER INSTALLATION (IF PRESENT)

EN
A
MECHANICAL INSTRUCTIONS
Remove the rear panel of the wired controller.
Fix the panel to the wall in the desired position.
Make the electrical connections to the wired controller (see B).
Fix the controller to the rear panel previously installed on the wall.
2x 5,30
B ELECTRICAL CONNECTION
SINGLE UNIT CONNECTION
WIRED CONTROLLER
MULTI CONFIGURATION: UP TO 5 UNITS
WIRED CONTROLLER
REAR PANEL DIMENSIONS
114,60
57,30
41,70
41,70
INDOOR UNIT
GND
+12V
INDOOR UNITS
GND
+12V
R1,62
Before installation, please cut off the power supply
of the indoor unit to which the wired controller is
connected.
A
Multipolar wire:
B
Electric cable 12V dc; section: 4 x 0,75mm
ATTENTION!
When inserting or removing connectors, press gently
on the clamp to facilitate the operation.
A
B
UNIT 1
ATTENTION!
The indoor units controlled by the wired controller
must all be connected to the same outdoor unit.
A
UNIT 2...
B
A
... UNIT 5
B
10
2,50
WARNING
2
.