Argo DD DCI Manual de instrucciones de instalación - Página 6

Navegue en línea o descargue pdf Manual de instrucciones de instalación para Aire acondicionado Argo DD DCI. Argo DD DCI 16 páginas. Air conditioner without outdoor unit

Argo DD DCI Manual de instrucciones de instalación
2.4 - DIMENSIONS AND WEIGHT
EN
Model
DD
DD DCI

3 - INSTALLATION

3.1 - INSTALLATION SITE SELECTION
AVOID
• Proximity to heat sources, exhaust fans.
• Proximity to combustible materials.
• Direct sunlight.
• Locations where the unit could be splashed with water
or affected by dampness or humidity (i.e. in laundries).
• Unsteady locations that will cause noise or possible
waterleakage.
• To make holes in areas where electrical wiring or
conduits are located.
min. 300
2000
min. 300
Weight (kg)
46
43
min. 800
LOW WALL INSTALLATION
IMPORTANT NOTES
• The wall must be a perimeter one.
• Select a sufficiently strong wall to support the weight of
the unit.
• Fix the unit at a minimum height of 30 cm.
• Leave a minimum operation and maintenance area
around the unit.(See figure).
• Make sure that there are no obstacles around the unit
affecting the free circulation of air.
• Avoid installing the unit with the air flow directly toward
passerby people, electric appliances or heat sources.
250
250
min. 300
6
HIGH WALL INSTALLATION
min. 300
250
250