Argo THOR Manual de instrucciones - Página 13

Navegue en línea o descargue pdf Manual de instrucciones para Aire acondicionado Argo THOR. Argo THOR 20 páginas.

3. FAN SPEED BUTTON

Press this button when the appliance is on to adjust the fan speed in cooling (AUTO), high (High), medium (Med),
low (Low).
The corresponding LEDs light up on the control panel according to the selection made.
The fan speed cannot be adjusted in DRY mode and is fixed at low.
4. UP/DOWN (+/-) BUTTONS
Press "+" or "-" to regulate the temperature (the adjustment step is 1 °C) and set the timer (each time the keys are
pressed, the adjustment step is 0.5 hours up to 9 hours, while from 10 to 24 hours the adjustment step is 1 hour).
The temperature ranges from 16 °C to 32 °C, and the time ranges from 0,5h to 24h

5. MODE BUTTON

Press this button to select the different operating modes, according to this sequence: Auto -> Cooling ->
Dehumidification -> Ventilation
In Cooling mode, Dehumidification and Ventilation modes, the display light up.
The corresponding LEDs light up on the control panel according to the selection made.

6. SLEEP BUTTON

In operating mode, press "SLEEP" to enter 10 hours of intelligent sleep mode. After 10 hours, the air
conditioner will exit Sleep mode to restore the previous mode.
In Sleep mode, press "SLEEP" again, or press "MODE" or "ON/OFF" to exit Sleep mode.
Note: Sleep function is not available in ventilation mode. In Sleep mode there is no variation of the fan speed. In
cooling mode, after the first hour, the set temperature increases by 1 °C, after the second hour it increases again
by 1 °C; after the 5th hour it decreases by 1C°, continues like this for another 3 hours and then exits the Sleep
function continuing to operate normally in cooling mode.

7. SWING BUTTON

Press this button to activate or deactivate the automatic swing of the horizontal air louvers.
TIMER BUTTON (on remote controller)
When the air conditioner is off, press "TIMER" to set a time to turn on the unit. Press "+"or "-" to set the hour,
and press "TIMER" again to confirm.
When the air conditioner is on, press "TIMER" to set the time to turn off the unit. Press "+" or "-" to set the
hour - and press "TIMER" again to confirm it within 5 seconds. Without any operation within 5 seconds, the
air conditioner will confirm the time automatically.
After setting the time, press "TIMER" again to cancel the time setting.
On the control panel, the LED corresponding to the Timer lights up.
TEMPERATURE DISPLAY AND ERRORS
With the exception of message P1, tank full, when an error occurs do not attempt to repair the air conditioner,
always take it to an Argoclima Assistance Centre, otherwise the guarantee will no longer be valid.
Problem
E1
E3
E4
E8
P1
V 04/23
Cause
Room temperature sensor failure.
Failure of temperature sensor on the
evaporator.
Lower DC motor error
Communication faults between main PCB
and display PCB.
Alarm of full water tank.
Solution
Contact a service centre.
Contact a service centre.
Contact a service centre.
Contact a service centre.
Connect the PVC pipe to the condensate
drain hole.
33