Cisco 3660 Series Manual de instalación - Página 8

Navegue en línea o descargue pdf Manual de instalación para Hardware de red Cisco 3660 Series. Cisco 3660 Series 8 páginas. E1/t1 isdn pri network modules
También para Cisco 3660 Series: Manual del usuario (17 páginas), Ficha de datos (8 páginas)

Cisco 3660 Series Manual de instalación
Installing the Alarm Terminal Block
Follow this procedure to install the alarm terminal block (see
port:
Turn OFF power to the router. However, to channel ESD voltages to ground, do not unplug the power
Step 1
cable.
Use 12- or 14-AWG copper wires to connect DC-input power to the terminal blocks.
Step 2
Strip the wire shielding so that approximately 0.38 in. (9.7 mm) of each wire is exposed.
Step 3
Figure 4-10 Alarm Terminal Block
NO P NC
Press the orange-colored release and insert a wire into a receptacle of the alarm terminal block. Two of
Step 4
the three receptacles must have wires installed (see
wires.
Note
Note
Plug the alarm terminal block into the alarm port on the Cisco 3660 chassis. (See
Step 5
Note
Figure 4-11 Connecting the Alarm Terminal Block to the Alarm Port
Reinstall network cables, and turn ON power to the router.
Step 6
NEBS Level 3 and ETSI Compliance Kit Installation Guide for Cisco 3620, Cisco 3640, and Cisco 3660 Routers
4-8
Always wire the P terminal and one of the other (NO and NC) terminals.
To remove wires, press the orange-colored release next to each receptacle.
Connect the alarm terminal block to either an AC power source rated maximum 25 VAC and
5A current rating, or a DC power source rated maximum 30V and 5A current rating.
Chapter 4
Installation on Cisco 3660 Routers
Figure
4-10) in the Cisco 3660 router alarm
Table
4-1). The spring-loaded connector retains the
Figure
4-11.)