Cisco AS5850 Manual de instalación del hardware - Página 27
Navegue en línea o descargue pdf Manual de instalación del hardware para Hardware de red Cisco AS5850. Cisco AS5850 30 páginas. Universal gateways
También para Cisco AS5850: Manual de consulta rápida (38 páginas)
Chapter 1
Cisco AS5850 Product Overview
maintenance bus (Mbus), which monitors voltage tolerance levels, temperature conditions, and power
failure in the enhanced AC-input power shelf. A grounding cable provides a ground connection from the
2400W AC-input power shelf to the chassis.
Figure 1-12
Figure 1-12 Cisco AS5850 2400W AC-Input Power Shelf—Rear View
For detailed specification tables, refer to
Power Module Safety Features (2400W AC-Input Power Shelf)
The power modules in the enhanced 2400W AC-input power shelf have the following safety features:
•
•
•
•
78-10573-06 0A
shows a rear view of a 2400W AC-input power shelf before installation.
-NEG (BLACK )
SIDE A
+POS (RED)
AC power modules installed in the enhanced AC-input power shelf are protected against overcurrent
by circuit breakers, and against overtemperature by internal protection circuits.
A spring-clip locking mechanism in the ejector lever/handles holds individual AC power modules
in place, and prevents the power module from vibrating or sliding out of the power bay and
dislodging from the power backplane. A small flat-blade screwdriver is needed to delatch the AC
modules. Pulling on the handles without properly releasing the latches can damage the modules.
Double grounding lugs (as per NEBS requirements) on both the enhanced AC-input power shelf and
the chassis provide electrical grounding.
The power modules are self-monitoring. Each power module monitors its own temperature and
internal voltages. An internal fan in each power module draws cooling air from the front of the
power shelf, through the power module, and out the rear of the power shelf. The power module
airflow is separate from the rest of the Cisco AS5850 components.
Internal monitoring data is passed to the chassis through the maintenance bus (Mbus) monitoring
system. You can view this data through a terminal connected to the RSC console port. The command
to display the monitoring information is described in the Cisco AS5850 Universal Gateway
Operation, Administration, Maintenance, and Provisioning Guide, available online at:
http://www.cisco.com/univercd/cc/td/doc/product/access/acs_serv/as5850/sw_conf/5850oamp/
index.htm
-NEG (BLACK )
J10
SIDE A
+POS (RED)
Appendix A, "Cisco AS5850 Specifications."
Cisco AS5850 Universal Gateway Hardware Installation Guide
Field-Replaceable Units
1-27