Argo-Hytos PRMX8-06 Instrucciones de uso - Página 2
Navegue en línea o descargue pdf Instrucciones de uso para Unidad de control Argo-Hytos PRMX8-06. Argo-Hytos PRMX8-06 4 páginas. Explosion-proof
SD2EX-B3
SD2EX-B4, SD2PX-B4
PVRMX3-103
For 110 V DC, 110 V AC and 230 V AC coils:
The valve coil is not intended for direct connection to an electrical distribution network. Interference filtering up to 30 MHz and surge protection
must be provided by the manufacturer of the device on which the valve is installed.
3. Solenoid Ordering Code
Explosion-proof solenoid,
inner diameter 22 mm
Housing size
DC voltage
connection box
+ Cable gland
AC voltage 50/60 Hz
fix installed cable
Solenoid Codes
Ordering No.
EX22-46/01200AT4-B
32754300
EX22-46/01200AT6-B
32754400
EX22-46/02400AT4-B
32041400
EX22-46/02400AT6-B
32754500
EX22-46/04800AT4-B
32754600
EX22-46/04800AT6-B
32754700
EX22-46/11000AT4-B
32754800
EX22-46/11000AT6-B
32754900
www.argo-hytos.com
Subject to change · Operating_Instructions_for_Explosion-proof_Valves_4090_2en_06/2018
Electrical Part of the Valve
Registry-No. of above authority: 0408
Declaration of conformity: K 19 / 2014
0408
Document:
B 32 / 2014
Data as of: 03.06.2014
1. Introduction
The solenoid was designed, manufactured, and tested in compliance with the standards and
regulations generally applicable within the European Union. On leaving the factory,
the solenoid's safety-related conditions were tested and proven to be faultless.
The operator must read and observe the notes and warnings provided with these operating
instructions to maintain this status and to ensure safe operation.
The solenoid must only be installed and wired by a qualified technician, who is familiar with and
works according to the generally accepted engineering standards and the latest legal regulations and
standards of explosion protection.
Surface treatment - Solenoid is zinc-coated with surface protection
acc. to ISO 9227 (520 h salt spray).
2. Usage
This solenoid is assigned to Group II, Category 2 of the ATEX directive and to Group I,
Category M2 for mining applications.
This device can be used in areas where explosion hazard occurs through:
- gas/air mixtures, vapours or mists of flammable materials
according to classes IIA and IIB acc. ATEX and IECEx.
- flammable dust/air mixtures
according to classes IIIA, IIIB and IIIC.
This device may be used in the following explosion hazard areas outside mining:
Zone 1, Zone 2, Zone 21 and Zone 22.
The maximum ambient temperatures are as follows:
Temperature class
T6 or rather T 80 °C (176 °F): Tamb= -30 °C (-22 °F) up to +45 °C (113 °F) and coil power P
T5 or rather T 95 °C (203 °F): Tamb= -30 °C (-22 °F) up to +55 °C (131 °F) and coil power P
T4 or rather T130 °C (266 °F): Tamb= -30 °C (-22 °F) up to +70 °C (158 °F) and coil power P
T4 or rather T130 °C (266 °F): Tamb= -30 °C (-22 °F) up to +60 °C (140 °F) and coil power P
EX22-46/
12 V DC
01200
24 V DC
02400
48 V DC
04800
110 V DC
11000
110 V AC
11050
230 V AC
23050
Solenoid Codes
EX22-460/1200BT4-B
EX22-46/02400BT4-B
EX22-46/04800BT4-B
EX22-46/11000BT4-B
EX22-46/11050AT4-3M-B
EX22-46/11050AT4-8M-B
EX22-46/11050AT6-3M-B
EX22-46/11050AT6-8M-B
-
-
B
zinc-coated (ZnNi), ISO 9227 (520 h)
No designation
3M
8M
T4
T6
A
B
Ordering No.
Solenoid Codes
32755000
EX22-46/23050AT4-3M-B
32755300
EX22-46/23050AT4-8M-B
32755400
EX22-46/23050AT6-3M-B
32755500
EX22-46/23050AT6-8M-B
32755600
EX22-46/11050BT4-3M-B
32755700
EX22-46/11050BT4-8M-B
32755800
EX22-46/23050BT4-3M-B
32755900
EX22-46/23050BT4-8M-B
=10 W
n
=10 W
n
=10 W
n
=18 W
n
Surface treatmen
Cable length
no cable (only for DC)
cable 3 m
cable 8 m
Temperature class
for 10 W, 18 W
for 10 W only
Solenoid nominal power
10 W
18 W
Ordering No.
32756000
32756100
32756200
32756300
32756400
32756500
32756600
32756700
Page 2