Cisco MSE 3365 Manual de instalación - Página 5

Navegue en línea o descargue pdf Manual de instalación para Servidor Cisco MSE 3365. Cisco MSE 3365 10 páginas.

Chapter 1
Overview
Table 1-1
Front Panel LEDs, Definitions of States (continued)
LED Name
5
System status
6
Fan status
7
Temperature status
8
Power supply status
9
Network link activity
State
Green—Cisco MSE 3365 is running in normal operating condition.
Green, blinking—Cisco MSE 3365 is performing system initialization and memory
check.
Amber, steady—Cisco MSE 3365 is in a degraded operational state. For example:
Power supply redundancy is lost.
CPUs are mismatched.
At least one CPU is faulty.
At least one DIMM is faulty.
At least one drive in a RAID configuration failed.
Amber, blinking—Cisco MSE 3365 is in a critical fault state. For example:
Boot failed.
Fatal CPU and/or bus error is detected.
Cisco MSE 3365 is in an over-temperature condition.
Green—All fan modules are operating properly.
Amber, steady—One or more fan modules breached the critical threshold.
Amber, blinking—One or more fan modules breached the non-recoverable
threshold.
Green—Cisco MSE 3365 is operating at normal temperature.
Amber, steady—One or more temperature sensors breached the critical threshold.
Amber, blinking—One or more temperature sensors breached the non-recoverable
threshold.
Green—All power supplies are operating normally.
Amber, steady—One or more power supplies are in a degraded operational state.
Amber, blinking—One or more power supplies are in a critical fault state.
Off—The Ethernet link is idle.
Green—One or more Ethernet LOM ports are link-active, but there is no activity.
Green, blinking—One or more Ethernet LOM ports are link-active, with activity.
Status LEDs and Buttons
Cisco MSE 3365 Installation Guide
1-5