Cisco SCE8000 GBE Manual de inicio rápido - Página 22
Navegue en línea o descargue pdf Manual de inicio rápido para Servidor Cisco SCE8000 GBE. Cisco SCE8000 GBE 25 páginas. 10gbe platform
También para Cisco SCE8000 GBE: Manual de configuración (18 páginas), Procedimientos de extracción y sustitución (36 páginas), Instalación de (21 páginas)
Table 8
Cisco SCE 8000 Operational States (continued)
Cisco SCE8000
Operational Status
Warning
Failure
Table 9
Power Supply LEDs
LED Label
Color
INPUT OK
Green
—
OUTPUT FAIL
Green
—
FAN OK
Green
—
Power (front panel)
Green
Amber
—
Table 10
Fan Assembly LED
LED Label
Color
FAN STATUS
Green
—
22
Description
Cisco SCE 8000 is fully operational (as above) but one of the following
occurred:
• GBE Management port link is down
• Temperature raised above threshold
• Voltage not in required range
• Fans problem
• Power supply issue
• Insufficient space on the disk
If the condition that caused the Cisco SCE8000 to be in Warning
Note
state is resolved (for example, link is up) the Cisco SCE8000 reverts
to Operational state.
After bootup, system is in Failure state due to one of the following
conditions:
• Power-on test failure
• Three abnormal reboots in less than 30 minutes
• Platform configured to enter Failure mode consequent to
failure-induced reboot (this is configurable using CLI command)
• Severe system health problem, such as extensive overheating or voltage
out of correct operating range
Depending on the cause of failure, the management interface and the
Note
platform configuration may or may not be active or available.
State
On
Off
On
Off
On
Off
Steady
Steady
Off
State
On
Off
Function
The input voltage is present and within the required range
The input voltage is not present or not within the required range.
The output voltage is not within the required range.
The output voltage is in the required range.
Power supply internal fan is operational.
Power supply internal fan is not operational.
Installed power supplies are functioning normally.
One of the power supply units is disconnected or malfunctioning.
No power.
Function
All fans are operational.
One or more of the individual fans are not operational.
Status LED State
Flashing amber
Red