Upgrading to a Cisco UCS B460 M4 Blade Server
Before you begin
• Ensure that the UCS B260 M4 Blade Module is installed in slot 7 in the chassis. This module will the
• Ensure that the UCS B260 M4 Blade Module from the upgrade kit is installed in slot 5 in the chassis.
Note
The KVM cable, USB flash device, and the SD cards must be configured in the UCS B260 M4 Blade Module
installed in slot 7. These components only operate in the master blade.
The following procedure describes installing a UCS B460 M4 blade server in slots 7 and 5. Other slot
combinations can also be used, including slots 5 and 3, and slots 3 and 1. However, the heaviest blade server
in the chassis should be installed in the lowest slots so if only one UCS B460 M4 is to be installed, then it
should go in slots 7 and 5.
Procedure
Step 1
Remove the UCS Scalability Terminator from the UCS B260 M4 Blade Module installed in slot 7. See
Removing the Scalability Terminator, on page
Step 2
Install the UCS B260 M4 Blade Module from the upgrade kit into slot 5 if the module is not already installed.
Step 3
Use the UCS Scalability Connector to connect together the blade modules in slot 7 and slot 5. See
a Scalability Connector, on page
Cisco UCS B260 M4 and B460 M4 Blade Server Installation and Service Note for Servers with E7 v3 and E7 v2 CPUs
Upgrading to a Cisco UCS B460 M4 Blade Server, on page 37
Removing the Scalability Terminator, on page 38
Installing a Scalability Connector, on page 38
be master in the UCS B460 M4 blade server.
C H A P T E R
38.
38.
4
Installing
37