Cisco UCS B440 M2 Hoja de especificaciones - Página 14

Navegue en línea o descargue pdf Hoja de especificaciones para Servidor Cisco UCS B440 M2. Cisco UCS B440 M2 40 páginas. Blade server
También para Cisco UCS B440 M2: Especificaciones (5 páginas)

CONFIGURING the SERVER
STEP 5
CHOOSE RAID CONFIGURATION
The B440 M2 server integrates the LSI SAS2108 6G SAS RAID controller.
Choose RAID Options
If desired, choose the RAID 5, 6 upgrade option and battery backup option listed in
BBU is an intelligent battery backup unit that protects disk write cache data during a power loss
on the RAID controller for up to 72 hours. We recommend that you replace the BBU once per
year or after 1,000 recharge cycles, whichever comes first.
Table 8 Available RAID Options
Product ID (PID)
RAID Battery Backup Option
N20-LBBU
RAID Configuration
N20-BRAID-K1
Caveats
No RAID option will be effective if you have a mix of SAS and SATA drives.
No RAID option is possible if you have no drives.
You must have at least one drive installed in order to add an optional battery backup unit.
14
PID Description
Battery backup unit for 1 GB write cache
RAID upgrade supporting RAID 5 and 6
Table
8. The
Cisco UCS B440 M2 Blade Server