Acuity Brands Lighting American Electric Lighting ATB0 Series Instrucciones de instalación

Navegue en línea o descargue pdf Instrucciones de instalación para Linterna Acuity Brands Lighting American Electric Lighting ATB0 Series. Acuity Brands Lighting American Electric Lighting ATB0 Series 2 páginas.

I N STALLAT I ON I N ST RU CT I ON S
DI SCON N ECT POWER BEFORE RELAM PI N G OR WI RI N G T H E FI X T U RE.
READ ALL I N ST RU CT I ON S COM PLET ELY BEFORE ST ART I N G I N ST ALLAT I ON
RI SK OF FI RE. PRODU CT FOR OU T DOOR I N ST ALLAT I ON AN D U SE ON LY .
T H I S I S AN ELCT RON I C DEV I CE AN D SH OU LD N OT BE LEFT EX POSED TO T H E ELEM EN T S
DU RI N G STORAGE, T RAN SPORTAT I ON , OR I N STALLAT I ON . I T I S RAT ED FOR OU T DOOR
U SE ON CE PROPERLY I N STALLED AN D I N N ORM AL CON DI T I ON .
T O AV OI D T H E RI SK OF FI RE OR SH OCK , FI X T U RE M U ST BE I N ST ALLED I N COM PLI AN CE WI T H ALL APPLI CABLE N AT I ON AL
AN D LOCAL ELECT RI CAL/BU I LDI N G CODES. FOR CODE I N T ERPRET AT I ON , CON SU LT LOCAL CODE AU T H ORI T Y
TERMINAL
BLOCK COVER
TERMINAL
BLOCK
WARN I N G
!
EN SU RE T H AT ALL POWER I S
DI SCON N ECT ED PRI OR T O WI RI N G
WIRING:
PULL UP TERMINAL BLOCK COVER (OPTIONAL) AS SHOWN IN
THE PICTURE. FEED THE SUPPLY WIRES THROUGH THE MAST
ARM, DRESS THEM SO THEY DO NOT INTERFERE WITH ANY
COMPONENTS AND SO THEY WILL NOT BE PINCHED IN THE
DOOR, AND CONNECT THEM TO THE PROPER TERMINALS ON
THE TERMINAL BLOCK. VERIFY THE SUPPLY VOLTAGE IS
CORRECT AS NOTED ON THE NAMEPLATE LABEL. IF SUPPLIED,
PUSH DOWN THE TERMINAL BLOCK COVER TO KEEP
TERMINALS COVERED.
WARN I N G
!
FI X T U RE M U ST BE GROU N DED
TO FU N CT I ON AS I N T EN DED
TERMINAL BLOCK:
RECOMMENDED TORQUE FOR SCREWS 35 IN-LBS.
DRAWING NO. A72974 REV: A (FRONT)
American Electric Lighting a division of Acuity Brands Lighting
AT B0 SERI ES LU M I N AI RES
!
!
!
!
KNOCKOUT
©2014 ACUITY BRANDS LIGHTING, INC. ALL RIGHTS RESERVED.
WARN I N G
WARN I N G
WARN I N G
CAU T I ON
OV ER-T ORQU I N G OF FI T T ER CLAM P BOLT S CAN
CREAT E CRACK S I N T H E H OU SI N G CAU SI N G
T H E FI X T U RE T O FALL T O T H E GROU N D.
MOUNTING / LEVELING
DETERMINE THE SIZE OF THE MAST ARM. THIS LUMINAIRE IS
DESIGNED TO ACCOMMODATE A MAST ARM FROM 1/1/4" TO 2"
DIA. THE LUMINAIRE IS FACTORY SET TO MOUNT TO THE 1-1/4"
ARM. TO MOUNT TO A 2" ARM, A MODIFICATION MUST BE MADE.
THE REAR OPENING MUST BE ENLARGED. KNOCKOUTS ARE
CAST-IN AROUND THE REAR OPENING FOR THIS PURPOSE. TO
REMOVE THIS EXCESS MATERIAL, STRIKE WITH A HAMMER OR
GRASP WITH PLIERS AND BREAK OFF.
STANDARD MOUNTING
LOOSEN (DO NOT REMOVE) THE FITTER BOLTS. LIFT THE
LUMINAIRE INTO POSITION IN FRONT OF THE MAST ARM SUCH
THAT THE MAST ARM ENTERS THROUGH THE OPENING AT THE
REAR OF THE LUMINAIRE AND BETWEEN THE FITTER BRACKET
AND THE LUMINAIRE HOUSING. TIGHTEN FITTER BOLTS
TO 10-12 FT-LBS.
OPTIONAL PHOTOCONTROL:
PLUG THE PHOTOCONTROL INTO THE RECEPTACLE ENSURING
GASKET IS FIRMLY SEATED. TWIST CLOCKWISE UNTIL IT LOCKS INTO
POSITION.
IF PHOTOCONTROL RECEPTACLE ROTATION IS REQUIRED, LOOSEN
THE TWO PHILIPS HEAD RECEPTACLE SCREWS. ROTATE
RECEPTACLE, MAXIMUM OF 360° , THEN RE-TIGHTEN SCREWS
UNTIL SNUG, USING 20-25 IN-LBS OF TORQUE.
IF PHOTOCONTROL RECEPTACLE ROTATION IS REQUIRED FOR THE
P5 / P7 OPTION, LOOSEN THE TWO PHILIPS HEAD RECEPTACLE
SCREWS COMPLETELY. ROTATE RECEPTACLE 90°, 180°, OR 270°,
THEN RE-TIGHTEN SCREWS UNTIL SNUG, USING 20-25 IN-LBS OF
TORQUE.
NOTE:
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES.
OPERATION IS SUBJECT TO THE FOLLOWING TO CONDITIONS:
(1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND
(2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED,
INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED
OPERATION.
5 YEAR LIMITED
WARRANTY
CAU T I ON
!
:
:
PART NUMBER 057-70-72974