Acuity Brands Lighting HYDREL Instrucciones de instalación - Página 2
Navegue en línea o descargue pdf Instrucciones de instalación para Luz de inundación Acuity Brands Lighting HYDREL. Acuity Brands Lighting HYDREL 4 páginas.
iNSTALLATiON iNSTRUCTiONS
WARNiNG:
FAILURE TO FOLLOW THESE INSTRUCTIONS AND WARNINGS MAY RESULT IN DEATH, INJURY OR SIGNIFICANT PROPERTY DAMAGE
For your protection, read and follow these warnings and instructions carefully before installing this fixture. These instructions do not attempt to cover all installation
situations. If you do not understand these instructions or additional information is required, contact Hydrel Lighting or your local Hydrel Lighting distributor.
Attach Mounting Plate Assemblies (A) to mounting surface using qty two (2) each ¼-20x1" socket head cap screw
1)
fasteners (B) provided and appropriate surface anchors (not provided).
a.
Mounting Plate Assemblies (A) should be spaced no further apart than 4" less than the fixture overall length.
b.
Two (2) Mounting Plate Assemblies (A) are required for RHY2, RHY3, & RHY4
c.
All customer supplied mounting anchors must be suitable for use in the mounting surface material, capable of
supporting fixture weight and meet all applicable building code requirements.
2)
Loosen fixture Track Screws (D) located on Fixture Assembly (C) ¼ - ½ turn so that Fixture Mount Slide (E) moves
freely along Fixture track.
3)
Slide Fixture Mount Slide (E) along fixture length until openings align with Mounting Plate Assembly rods.
4)
Attach Fixture Mount Slide (E) to Mounting Plate Assembly rod and tighten qty two (2) each 10-32 set screws (F)
on each Mounting Plate Assembly (A).
5)
Re-tighten Track Screws (D).
6)
Rotate fixture to aim as required and tighten qty. two (2) each ¼-20 Slide Screws (G) on each Fixture Mount Slide (E).
A
Mount Plate Assembly
B
¼-20x1" socket head cap fastener
Fixture
C
D
Track Screws
E
Fixture Mount Slide
F
10-32 Set Screws
G
¼-20 Slide Screws
EXTENDED ARMS & STRUTS
9144 Deering Avenue | Chatsworth, CA 91311 | www.hydrel.com
Phone: 866.533.9901 | Fax: 866.533.5291
RHYTHM SERiES
Installation should be performed by a qualified
electrician in accordance with the National Electrical Code
and relevant local codes.
B
A
C
G
E
D
F
©2014 Acuity Brands Lighting, Inc.
INS-RHYTHM
7/29/14