Performance Charts
Test Conditions: Pump tested in water with inlet submerged.
Operating Air Pressure
A
125 psi (0.83 MPa, 8.3 bar)
B
100 psi (0.7 MPa, 7.0 bar)
C
70 psi (0.48 MPa, 4.8 bar)
D
40 psi (0.28 MPa, 2.8 bar)
How to Read the Charts
1. Locate fluid flow rate along
bottom of chart.
2. Follow vertical line up to
intersection with selected
operating air pressure
curve.
3. Follow left to scale to read
fluid outlet pressure
(top chart) or
air consumption
(bottom chart).
28
120
(0.83. 8.3)
100
(0.7, 7.0)
80
(0.55, 5.5)
60
(0.41, 4.1)
40
(0.28, 2.8)
20
(0.14, 1.4)
0
0
5
(19)
(38)
28
56
80
(2.24)
Air Consumption
60
(1.68)
40
(1.12)
20
(0.56)
0
0
5
10
(19)
(38)
Cycle Rate
56
84
112
140
A
B
C
D
10
15
20
25
(57)
(76)
(95) (114) (133) (152) (170) (189)
Fluid Flow — gpm (lpm)
Cycle Rate
84
112
140
15
20
25
(57)
(76)
(95) (114) (133) (152) (170) (189)
Fluid Flow — gpm (lpm)
168
196
224
252
Fluid Pressure
30
35
40
45
168
196
224
252
A
B
C
D
30
35
40
45
859.0088
280
50
280
50
21