Epson EMP 7800 Manual del usuario - Página 6

Navegue en línea o descargue pdf Manual del usuario para Software Epson EMP 7800. Epson EMP 7800 28 páginas. Projector
También para Epson EMP 7800: Hoja de referencia de inicio rápido (7 páginas), Manual de introducción (10 páginas), Especificaciones (4 páginas), Manual del usuario (24 páginas), Manual del usuario (25 páginas), Manual del usuario (25 páginas), Folleto y especificaciones (4 páginas), Manual del usuario (28 páginas), Manual de consulta rápida (16 páginas)

Epson EMP 7800 Manual del usuario
S5/X5/83/822/83+/822+/EX90
G5350/G5300/G5150/G5100/
1735W/1730W/1725/1720
84/85/824/825/826W
Z8000WU/Z8050W
4.2.Power on state (operation indicator is in green)
All commands are executable.

5.Error Status

A projector returns the error status when a projector receives "ERR?" command.
The following projectors can return the error status while the projectors become the cool-downs status at an error and the projectors become
the error status after cooling down.
EMP-1700/1705/1710/1715, 6000/6100/6110/6010, 1815/1810/1825, S5/X5/83/822, 260/280, 400W/410W
EB-G5000/G5100/G5150/G5200W/G5300/G5350
And later models.
[The other models except the above models]
The models except the above models can return the error status while the projectors become the cool-downs status at an error.
The following table shows the return codes and the meaning of error status.
Command
ERR?
ESC/VP21 Command User's Guide for Business Projectors
Model s
62/82
X3(76)
6100/6000
1715/1705
1815/1810/1825
260/280
6110/6010
400W/410W
G5200W/G5000
S6/X6/W6
00
:There is no error or the error is recovered
01
: Fan error
03
: Lamp failure at power on
04
: High internal temperature error
06
: Lamp error
07
: Open Lamp cover door error
08
: Cinema filter error
09
: Electric dual-layered capacitor is disconnected
0A
: Auto iris error
0B
: Subsystem Error
0C
: Low air flow error
0D
: Air filter air flow sensor error
0E
: Power supply unit error (Ballast)
0F
: Shuter error
10
: Cooling system error (peltiert element)
11
: Cooling system error (Pump)
Power Consumption
Network off
about 4.0W
about 5.0W: 230V area
about 0.4W
about 3.8W
about 2.6W
about 4.1W
about 4.1W
about 0.4W
about 4.2W
about 0.4W
about 3W
about 4.0W
about 5.0W
TBD
Returne code
6 of 28
Network on
about 25W
about 23W: 120V area
(only 62/82)
about 10W
about 18W
about 12W
about 5W
(only 83/822)
about 4.1W
(only 280)
about 10.4W
about 4.9W
about 10W
-
about 9.0W
about 12W
TBD