Troubleshooting guide
Problem
High input
voltage alarm,
protection
(shutdown)
Low input voltage
alarm, protection
(shutdown)
Overload protection
(shutdown)
Overtemp
alarm, protection
(shutdown)
DIP Switch Function
S1
S2
S3
60HZ
50HZ
Freq.
PWR. SAV.
&
Bypass
possible cause
Battery voltage too high Reduce input volts
Battery voltage too low
AC load watts is too high
Inverter temperature
is too high
S2
0 OFF
ON
O N
ON
OFF
1 2 3
OFF
Change battery or
recharge battery
Reduce load on the
inverter./ Solve short
circuit situation.
Allow the inverter to cool.
Roduce the load if
continuous operation is
reguired.
S3
ON
Power sav. count down time 30sec.
OFF
Power sav. count down time 10sec.
Bypass OFF
ON
Bypass ON
OFF
solution
Power sav. OFF
Power sav. OFF