If unit was operating prior to servicing allow at least 10 minutes for light bulbs and
heating element to cool off to avoid accidental burning of skin.
Disconnect power before attempting any maintenance or cleaning to reduce the risk of
electric shock or damage to persons.
Light bulbs need to be replaced when you notice a dark section of the flame. There are
four bulbs under the log set which generate the flames and embers.
It is a good idea to replace all of the light bulbs at one time if they are close to the end of
their rated life. Group replacement will reduce the number of times you need to open
the unit to replace the light bulbs.

LOWER LIGHT BULB REPLACEMENT

1. Gently place stove on it's back on a flat surface.
2. Remove the thermostat knob.
3. Remove the heater cover retaining screws located on the bottom of the stove and
lower heater/light assembly onto the floor.
4. Remove the burnt out bulbs by pulling straight out of the socket. If bulbs are difficult
to remove from socket, move bulb from side to side while pulling, being careful not to
damage the light socket.
5. Replace lower light bulbs
6. Caution should be taken not to touch the glass portion of the new halogen bulbs.
Doing so may lead to shorter bulb life.
7. Reassemble in the reverse order as above.
LIGHT BULB REQUIREMENTS
Quantity of 3 -35 watt Halogen Quartz lamps, 120 volt, G9 base