Dimplex DLGM29 Manual de servicio - Página 10

Navegue en línea o descargue pdf Manual de servicio para Calentador eléctrico Dimplex DLGM29. Dimplex DLGM29 10 páginas. Log grate
También para Dimplex DLGM29: Manual del usuario (20 páginas)

Dimplex DLGM29 Manual de servicio
PROBLEM
Mist is coming out fast
Mist appears to be "falling"
Mist does not appear to be com-
ing out evenly
10
CAUSE
Filter is missing off of Fan Housing
Loose connection
Defective Heater
Unit is not level
Log arrangement is blocking air flow
Light Lenses are not correctly oriented
Light Lenses are not present
SOLUTION
Replace Fan Filter
Check heater wiring connections
Replace Heating assembly
Level unit
Rearrange logs
Adjust Lenses
Replace light lenses