Aeon Labs Aeotec Smart Switch 7 Manual de inicio rápido - Página 5
Navegue en línea o descargue pdf Manual de inicio rápido para Interruptor Aeon Labs Aeotec Smart Switch 7. Aeon Labs Aeotec Smart Switch 7 9 páginas.
Setting
0
1 - 2415
Parameter 8: Alarm Response
Enabled by (Alarm Settings), and determines what the switch does in the case an alarm is triggered.When
receives any alarm enabled by Alarm Settings, Indicator Light will keep blinking based on Parameter 0x12 (18).
It will prohibit user from manually or RF control the switch state until the alarm is disable.
Size: 1 Byte, Default Value: 0
Setting
0
1
2
3
Parameter 9: Alarm Settings
Determine if alarms are enabled in Switch, and what Switch will react to which alarm. The format of the
parameter is Bit field (Checkboxes). The parameter MUST be treated as a bit field where each individual bit can
be set or reset. A graphical configuration tool SHOULD present this parameter as a series of checkboxes. Please
refer to the manual for more details about supported Notification Type and Notification Event.
Size: 2 Byte, Default Value: 0
Setting
1
256
512
1024
2048
4096
8192
16384
Parameter 10: Setting to disable alarm
Determines the method of disabling the alarm of the device.Note:Power off will also disable the alarm response
without any limitation.
Size: 2 Byte, Default Value: 0
Setting
0
1
10 - 255
Description
Disable over-load protection
Threshold power is 1-2145W
Description
Disable, no reaction to alarm settings
Switch is ON
Switch is OFF
Switch will turn ON in 5 seconds, and then turn OFF in 5 seconds in a cycle until user disables
the alarm manually
Description
Access Control trigger state
Smoke Alarm
CO Alarm
CO2 Alarm
Heart Alarm
Water Alarm
Access Control
Home Security
Description
Can be disabled by 3x tapping Action Button within 1 second
Can be disabled when receives a State Idle corresponding to the alarm. Note: If Access Control is
enable, it also can be disabled when receives the reversal state of window/door.
Sets the duration of the alarm in seconds(i.e. Customer sets this setting to 50, the alarm state of
the Switch will disable after 50 seconds)