Parameter 18: LED blinking frequency
When receiving the enable Alarm, it will flash according to the blink frequency configured by this parameter
until the Alarm is disable. Brightness level and color is based on current indicator. If the value of brightness
level and color is 0, it will flash based on last visible color.
Size: 1 Byte, Default Value: 2
Setting
1 - 9
Parameter 19: Start or stop LED blinking.(Write Only)
The parameter can be used to test the effect of LED blinking.
Size: 2 Byte, Default Value: 0
Setting
0
1 - 255
Parameter 20: Action in case of power out.
Action in case of power out.
Size: 1 Byte, Default Value: 0
Setting
0
1
2
Parameter 80: Configure what command will be sent via Lifeline when switch state has changed.
Configure what command will be sent via Lifeline when switch state has changed.
Size: 1 Byte, Default Value: 2
Setting
0
1
2
Parameter 81: Load Indicator Mode setting.
Note: Configuring brightness and color of Indicator Light in different time/status of different modes will be
saved in the current setting mode. Please refer to the manual for more details.
Size: 1 Byte, Default Value: 2
Setting
0
1
2
Parameter 82: Configure the enable and disable time of Night Light Mode
If you want to set Night Light Mode to be enable at 19:00 at night and disable at 07:30 in the morning, you just
need to configure:Value1=0x13, Value2=0x00, Value3=0x07, Value4=0x1E.
Size: 4 Byte, Default Value: 301991936
Description
Set amount of blinks per seconds.
Description
Stop blinking.
Set the duration and start the blinking process. * This sets the timeframe of blinking in seconds. *
Once the duration ends, the blinking will stop.
Description
Last status
Switch is on
Switch is off
Description
None
Basic Report
Binary Switch Report
Description
Disable Mode
Night Light Mode
ON/OFF Mode