3. Remove MultiSensor from Z-wave network:
1. Power on MultiSensor. The MultiSensor's LED will be kept turning on for 8 seconds when you short press
the Action Button.
2. Let the primary controller into exclusion mode (If you don't know how to do this, refer to its manual).
3. Press the Action Button.
4. If the exclusion is success, MultiSensor's LED will blink slowly when you short press the Action Button. If
MultiSensor's LED still keeps on status, in which you need to repeat the process from step 2.
Short press 2 times
1. Send Security Node Info frame.
within 1 second
2. Add MultiSensor into z-wave network:
1. Power on MultiSensor. The MultiSensor's LED will blink slowly when you short press the Action Button.
2. Let the primary controller into inclusion mode (If you don't know how to do this, refer to its manual).
3. Press the Action Button.
4. If the inclusion is success, MultiSensor's LED will be kept turning on for 8 seconds when you short press the
Action Button. If the LED is still in slow blink, in which you need to repeat the process from step 2.
3. Remove MultiSensor from Z-wave network:
1. Power on MultiSensor. The MultiSensor's LED will be kept turning on for 8 seconds when you short press
the Action Button.
2. Let the primary controller into exclusion mode (If you don't know how to do this, refer to its manual).
3. Press the Action Button.
4. If the exclusion is success, MultiSensor's LED will blink slowly when you short press the Action Button. If
MultiSensor's LED still keeps on status, in which you need to repeat the process from step 2.
Press and hold for 3
Enable/disable wake up for 10 minutes.
seconds
(When it is enabled, the orange Led will fast blink)
Press and hold for
Reset MultiSensor to factory Default:
20 seconds
1. Press and hold the Action Button for 20 seconds.
2. If holding time more than one second, the LED will blink faster and faster. If holding time more than 20
seconds, the LED will be on for 2 seconds, which indicates reset is success, otherwise please repeat step 2.
Note:
1, This procedure should only be used when the primary controller is inoperable.
2, Reset MultiSensor to factory default settings, it will:
a ), let the MultiSensor to be excluded in Z-Wave network;
b), delete the Association setting, power measure value, Scene Configuration settings;
c), restore the Configuration settings to the default.
5. Special Rule of Each Command
5.1 Z-Wave Plus Info Report Command Class
Parameter
Z-Wave Plus Version
Role Type
Node Type
Installer Icon Type
User Icon Type
Value
1
6(ZWAVEPLUS_INFO_REPORT_ROLE_TYPE_SLAVE_ALWAYS_ON)
0 (ZWAVEPLUS_INFO_REPORT_NODE_TYPE_ZWAVEPLUS_NODE)
0x0C07 (ICON_TYPE_SPECIFIC_SENSOR_NOTIFICATION_HOME_SECURITY)
0x0C07 (ICON_TYPE_SPECIFIC_SENSOR_NOTIFICATION_HOME_SECURITY)