43 (0x2B)
Threshold change in luminance to induce an automatic report.
44 (0x2C)
Threshold change in battery level to induce an automatic report.
Note:
1.
The unit is %.
2.
The default value is 10, which means that if the current battery level gap is
more than 10%, it will send out a battery report.
45 (0x2D)
Threshold change in ultraviolet to induce an automatic report.
Enable/disable to send the alarm report of low temperature(<-15
46 (0x2E)
Value=0, disable.
Value=1, enable (The MultiSensor will send a report of Multi Level Temperature
CC to controller if the current temperature is less than -15
Note: The battery activity will be reduced at low temperatures (-15 degrees
Celsius and below), which will lead to the product may not work normally. It is
recommended to use USB power at low temperatures.
100 (0x64)
Set 101-103 to default.
101 (0x65)
Which report needs to be sent in Report group 1 (See flags in table below).
102 (0x66)
Which report needs to be sent in Report group 2 (See flags in table below).
103 (0x67)
Which report needs to be sent in Report group 3 (See flags in table below).
110 (0x6E)
Set 111-113 to default.
111 (0x6F)
The interval time of sending reports in Report group 1 (Valid values 0x05-
0x28DE80).
1. The unit of interval time is second if USB power.
2. If battery power, the minimum interval time is 60 minutes by default, for
example, if the value is set to be more than 5 and less than 3600, the interval
time is 60 minutes, if the value is set to be more than 3600 and less than 7200,
the interval time is 120 minutes. You can also change the minimum interval time
to 4 minutes via setting the interval value(3 bytes) to 240 in Wake Up Interval Set
CC.
112 (0x70)
The interval time of sending reports in Report group 2 (Valid values 0x05-
0x28DE80).
Note:
1. The unit of interval time is second if USB power.
2. If battery power, the minimum interval time is 60 minutes by default, for
example, if the value is set to be more than 5 and less than 3600, the interval
time is 60 minutes, if the value is set to be more than 3600 and less than 7200,
the interval time is 120 minutes. You can also change the minimum interval time
to 4 minutes via setting the interval value(3 bytes) to 240 in Wake Up Interval Set
CC.
100 (LUX)
10 (%)
2
)
℃
0
℃
) .
-
241
0
0
-
3600 (seconds)
3600 (seconds)
2
2
1
1
-
4
4
4
-
4
4