Maintenance
Thermal Safety Cut outs
1)
Pass flat head screwdriver through air
outlet grill to centre panel side of reset button.
2)
Press buttons in directions shown to
reset cut-outs. Cut-out clicks when reset.
3)
Remove screwdriver carefully.
Cleaning

After Sales Service

This product complies with the European standard for Electromagnetic Compatibility (EMC) ENS5014, EN60555-2 and
EN60555-3 which cover the essential requirements of EEC Directive 891336.
Glen Dimplex UK Limited
Millbrook House
Grange Drive
Hedge End
Southampton.
Hampshire, SO30 2DF
WARNING: DISCONNECT SUPPLY before carrying out
maintenance.
Two cut-outs are fitted to the heater, situated on the end of the heat exchanger, and
accessible as described below * * . The cut-outs will operate if the appliance
overheats for the following reasons.
a)
Air inlet louvered panel obstructed.
b)
Air outlet grille obstructed.
c)
Fan motor stalled or slow start due to build-up of dirt or fluff.
Rectification procedure:
a)
Establish cause and eliminate.
b)
Reset thermal cut out (s) by depressing black button on side of cut out as
described in 1 - 3 below.
Centre Panel
External appearance can be maintained by wiping occasionally with a damp cloth;
for stain removal, a weak soap solution can be applied, then wipe dry.
Internal cleaning should be carried out periodically to maintain the performance of
the heater. Remove the louvered front panel and clean the inside of the heater of
fluff and dust, using a small soft dry brush or vacuum cleaner attachment, taking
extreme care not to disturb internal wiring.
Your Dimplex Air Curtain is guaranteed for one year from date of purchase. We
undertake to exchange or repair free of charge within this period any part found to be
defective due to a manufacturing fault. This guarantee in no way prejudices your
rights under common law.
Should you require after sales service, please get in touch with the supplier through
whom you purchased the appliance, or your nearest service agent.
Please do not initially return a faulty appliance or part of an appliance to us as this
may result in transit damage and or delay in providing service. Let us know your
difficulty, quoting the model number and series letter of the appliance. We will then
take the appropriate action.
UK customer helpline (8.00am – 6.00pm Mon-Fri; 8.30am-1.00pm Sat)
Customer Services:
Tel. 0870 7270101
Fax. 0870 7270102
Republic of Ireland
01 8424833
Air Outlet
Grille
Tel: +44 (0)191 490 1547
Fax: +44 (0)191 477 5371
Email:
Website:
www.heattracing.co.uk
www.thorneanderrick.co.uk
issue 1. 10/10/95