- New Test Mode(aging operation and setup analysis)
The single CD player plays in normal mode. After being set up, it will display FOK (focus), LOCK (spindle), subcode,
sound skip, protection against a mechanical error or the like, occurrence of an error, cause and time of an expiry, if
any, (and disc number)
During the setup, the CD software operation status (internal RAM and C-point)is displayed.
(1) How to enter NEW TEST Mode
See the test mode flow chart Page 43.
(2) Relations of keys between TEST and NEW TEST Modes
Keys
Test Mode
Regulator OFF Regulator ON
BAND
Regulator ON
FWD
REV
A
D
B
C
To New Test
Mode
Operations,such as EJECT, CD ON/OFF, etc. are performed normally
(3) Indicating an Operation Status During Setup
Status No. Description
01
Carriage home mode started
02
Carriage moving inwards
03
Carriage moving outwards
05
Carriage moving outwards
11
Setup started
12
Spindle turn/Focus search started
13
Waiting for focus closure (XSI=L)
10,14
Waiting for focus closure (FOK=H)
15, 16, 17
Focus closed, Tracking open
18
During focus AGC
19
During tracking AGC
20
Waiting for MIRR, LOCK or subcode read
Carriage closed, SPINDLE=ADAPTIVE
44
New Test Mode
PLAY in progress
Regulator OFF
FWD-Kick
FF/TRACK+
REV-Kick
REV/TRACK-
Tracking close
SCAN
Tracking open
MODE
Focus close
Focus open
Jump OFF
Jump Mode
AUTO/MANU
Select
Error Occurred,
Protection Activated
Time of occurrence/
cause of error select
TRACK No./
time of occurrence select
Protection operation
None
10-second time out, Home switch failed
10-second time out, Home switch failed
None
None
None
Failure to close focus
Failure to close focus
Focus disrupted
Focus disrupted
Disrupted focus
Focus disrupted, MIRR NG, Failure to lock,
failed to read subcode