DINA DN3PD1 Manual de instrucciones original - Página 10
Navegue en línea o descargue pdf Manual de instrucciones original para Instrumentos de medida DINA DN3PD1. DINA DN3PD1 20 páginas. Speed monitoring for one and three phases motors without sensor system
También para DINA DN3PD1: Manual de instrucciones temporal (8 páginas)
DN3PD1
Function description
Schematic, operating element and display
L1
SET
24 V DC
A1 A2 O1 O2
Terminal description
A1/ A2
Power supply 24V DC
L1, L2, L3
Measuring inputs are to be connected directly to the motor, without switching contacts between.
Q
Acknowledgment input can be parameterized, manually or automatically
13/14, 23/24
Enabling contacts (2 NO-contacts). These switch off immediately if the parameterized speeds are
undershot or exceeded or internal or external errors.
13/14, 23/24 are to be used in such a way that the intended safety function, e.g. emergency stop is
executed.
O1, O2
Digital positive switching semiconductor outputs for the transmission of switching states to a
higher-level control for diagnostic tasks.
10
L2
L3
b8
OK
b4
SPEED
b2
b1
Q
13 14 23 24
L1, L2, L3
Measuring inputs
A1
Power supply
+24V DC
A2
0V
Q
Acknowledgment in-
put
O1, O2
Diagnostics outputs
13-14/23-24
Enabling contacts
SET
Configuration button
b1, b2, b4, b8 parameter 1-15
OK
Ready for operation
SPEED
Speed Status
18-09-27 / 33pd02-V0743