7. DOOR SWITCH

Fig. 7-1

8. WATER VALVES

• To remove either Water Valve, first remove its rear mounting screw (Fig. 8-1), then remove the Top Panel as described in Section 2.
Then remove the two (2) Phillips screws for the Valve being replaced (Fig. 8-3). When you remove the valve be careful that you also
remove the Valve Seal (Fig. 8-2) which may still be inserted into the Dispenser Housing. It will be easier to mount the new Water
Valve into the Dispenser Housing if the Valve Seal is already fitted to the Water Valve when replaced.
REPAIR MANUAL
• To remove the Door Switch, remove the two (2) T-15 Torx screws (Fig. 7-1). Then remove the
Top Panel as described in Section 2. With the Top Panel removed disconnect the wire harness
from the Door Switch and replace (Fig. 7-2).
Fig. 8-1
Fig. 8-2
AW 120 / AW 122 / AW 125
AWD 120 / AWD 121 / AWD 129
Fig. 7-2
Fig. 8-3