22mm COLD
MAINS IN
SERVICEABLE 3/4" PRESSURE REDUCING
CARTRIDGE AND LINE STRAINER
(SET AT 3.5 BAR)
22mm COLD
MAINS IN
F
. 2.7
IG
SERVICEABLE 1" PRESSURE REDUCING
CARTRIDGE AND LINE STRAINER
(SET AT 3.5 BAR)
28mm COLD
MAINS IN
F
. 2.8
IG
3.5
22mm BALANCED COLD WATER TAKE OFF
WITH NON-RETURN VALVE
3/4" B.S.P. CONNECTION
FOR EXPANSION VESSEL
6 BAR
15mm EXPANSION RELIEF
OUTLET TO TUNDISH
EXPANSION RELIEF VALVE
(SET AT 6 BAR)
NON-RETURN VALVE
(WITHIN HOUSING)
1" BALANCED COLD WATER TAKE OFF
WITH NON-RETURN VALVE
9
22mm TO WATER HEATER
22mm TO CYLINDER
EXPANSION RELIEF VALVE
(SET AT 6 BAR)
28mm TO
CYLINDER
3/4" B.S.P. CONNECTION
FOR EXPANSION VESSEL
For 500 litre
Models