Ariston 500 STI UK Manual de instrucciones para la instalación - Página 9
Navegue en línea o descargue pdf Manual de instrucciones para la instalación para Calentador de agua Ariston 500 STI UK. Ariston 500 STI UK 24 páginas. Unvented hot water storage cylinders
22mm COLD
MAINS IN
SERVICEABLE 3/4" PRESSURE REDUCING
CARTRIDGE AND LINE STRAINER
(SET AT 3.5 BAR)
22mm COLD
MAINS IN
F
. 2.7
IG
SERVICEABLE 1" PRESSURE REDUCING
CARTRIDGE AND LINE STRAINER
(SET AT 3.5 BAR)
28mm COLD
MAINS IN
F
. 2.8
IG
3.5
22mm BALANCED COLD WATER TAKE OFF
WITH NON-RETURN VALVE
3/4" B.S.P. CONNECTION
FOR EXPANSION VESSEL
6 BAR
15mm EXPANSION RELIEF
OUTLET TO TUNDISH
EXPANSION RELIEF VALVE
(SET AT 6 BAR)
NON-RETURN VALVE
(WITHIN HOUSING)
1" BALANCED COLD WATER TAKE OFF
WITH NON-RETURN VALVE
9
22mm TO WATER HEATER
22mm TO CYLINDER
EXPANSION RELIEF VALVE
(SET AT 6 BAR)
28mm TO
CYLINDER
3/4" B.S.P. CONNECTION
FOR EXPANSION VESSEL
For 500 litre
Models