NOTE: Elements burn through commissioning without water and burnouts due to loose connections are
not covered by the Warranty.
For greater safety, have qualified personnel carry out a careful inspection of the electrical system, ensur-
ing it complies with the applicable norms in force, because the appliance manufacturer will not be held
responsible for any damage caused by the lack of earthing of the system or for faults in the electricity
supply.
Check that the system is suitable for the maximum power absorbed by the water heater (please refer
to the data plate) and that the cross-section of the electrical connection cables is suitable and complies
with current laws. The use of multiplugs, extensions or adaptors is strictly prohibited. It is strictly forbid-
den to use the piping from the plumbing, heating and gas systems for the appliance earthing connection.
If the appliance is supplied with a power supply cable and the latter should need replacing, use a cable
featuring the same characteristics (type H05VV-F 3x1.5 mm², 8.5 mm in diameter) and compliant with
SANS 60227-5. The supply cable (type H05 VV-F 3x1.5 mm²) is to be inserted in the proper hole situated
in the back of the appliance and slide it until it reaches terminal of the thermostat, then lock single cables
by mean of the insulation base. To disconnect the unit from the electrical supply use a bipolar, switch
conforming to local (contact opening at least 3 mm, better if equipped with fuses).
The appliance must be earthed and the earth cable (which must be yellow-green and longer than that
of the phases it is fixed to the terminal marked by the symbol
small cap using the special wire clamp provided.
Before usage, make sure that the supply voltage is in compliance with the rated values of the ap-
pliance. If the appliance is not supplied with a power supply cable, use a flexible cable (type H05VVF
3X1.5mm2, 8.5 mm) in diameter compliant with the applicable norms in force, if the applianche is sup-
plied with a cable clamp.
Startup and commissioning
Before powering up the appliance, fill the heater with mains water.
To do so, open the mains cock and the hot water tap until all the air has been vented from the
boiler. Check for leaks from the flanges, tighten down the fittings (not too much!) if necessary
(A fig. 4). Power up using the switch and in models with no switch, power up by turning the
adjustment knob clockwise
MAINTENANCE REGULATIONS (for competent person)
CAUTION: Observe all general warnings and safety standards listed at the beginning
of this text in full; all such instructions are obligatory.
Maintenance work may only be done by qualified technicians (in possession of the regulatory requi-
sites). Before requesting for the Technical Assistance to intervene for a suspected fault, check that this
is not caused by a temporary lack of water supply or power failure.
Draining the appliance
Make sure to drain the appliance when it is out of service or in an area subject to subzero
temperatures.
To drain the appliance, proceed as follows:
- permanently disconnect it from its power supply;
- open the hot water tap (sink or bath tub).
. Block the power supply cord on the
7 / EN