Installation Instructions:
The appliance must be installed and commissioned by a competent person in accordance with established
regulations and local health and safety regulations.
1.
Before performing any operations, disconnect the electricity using the external switch
2.
Open the two screws located at the bottom of the device and remove the cover from base.
3.
Fix the base horizontally against a wall or side of cabinet, the inlet and outlet water pipes are on the
down/bottom side of the unit. Use the four mounting screws provided.
44 mm
Use the supplied water filter on the inlet water pipe line (see diagram)
4.
5.
Connect the incoming cold water pipe to the inlet connection point on the bottom right side and the
outgoing hot water pipe to the outlet water pipe on the bottom left side. Turn open the of water supply and
check there is no water leakage from the unit.
6.
Use an all pole switch conforming with national laws in force (contact gap of at least 3 mm, preferably
equipped with fuses) to disconnect the appliance's power supply.
7.
Connect the power cable to the terminal block inside the unit. The appliance must be earthed and the earth
cable must be fixed to the terminal marked by the symbol
8.
Turn on the unit and check that it is operating as required.
9.
Reconnect the cover to the base with 2 screws.
10. It is required that a Ground Fault Circuit Interrupter/Earth Leakage Circuit Breaker be incorporated in the circuit.
11. Make sure to install the pressure relief valve correctly (supplied with the product) before Inlet pipe.
12. It is required to install a flow control restrictor (AERATOR) at the sink or shower.
13. WARNING: UNIT MUST BE PROPERLY GROUNDED
14. THIS HEATER MUST HAVE ITS OWN INDEPENDENT CIRCUIT USING A CORRECTLY RATED CIRCUIT
BREAKER AND SUITABLE WIRE, SEE TABLE RECOMMENDED CABLE.
240 mm
176 mm
20 mm
.
5
Flow restrictor
AERATOR
cable
Hot
Cold
water
water in
out
only