UPOZORENJE!
Svaki puta kada je mikroprekidač 1 uključen u
poziciji ON trebate postaviti maksimalnu i
minimalnu snagu.
Provjeravanje snage sporog paljenja
(vidi tablicu plinova)
1.
Zatvorite plinski ventil
2.
Otpustite vijak "a" i umetnite spojnu cijev mjerača tlaka
u slavinu
3.
Otvorite plinski ventil
4.
Izvadite baterije
5.
Okrenite mikroprekidač 1 u poziciju ON i zamijenite
baterije. Otvorite toplu vodu.
( Testni način ON-titra narančasti LED)
6.
Okrenite mikroprekidač 3 poziciju ON
(Uređaj prisiljen na snagu paljenja)
7.
Postavite polagano paljenje narančastim vijkom
8.
Mikroprekidač 3 stavite u poziciju OFF
9.
Stavite mikroprekidač 1 u poziciju OFF ( testni način
OFF) LED je narančast, sve postavke su pohranjene
10. Na kraju provjere, zatvorite plinski ventil i provjerite
zategnutost vijka
UPOZORENJE!
Postavke maksimalnog / minimalnog tlaka i
provjere usporenog paljenja moraju se napraviti
odvojeno, u skladu s uputama i dovršavanjem
postupka.
OFF
Jumper
Led
1. Regulacija potenciometra maksimum/minimum i
polako paljenje
2. Mikroprekidač
puštanje u rad
ON
1 2 3 4 5 6 7 8
WARNING: Every time microswitch 1 is turned to
ON, you need to set both maximum and minimum
power.
Checking slow ignition power
(see the Gas setting table)
1.
Close the gas valve
2.
Loosen screw "a" and insert the manometer connection
pipe into the pipe tap.
3.
Open the gas valve
4.
Remove the batteries
5.
Turn microswitch 1 to ON position and re-place the
batteries. Open one hot water tap.
(Test Mode ON - Flashing orange LED)
6.
Turn microswitch3 to ON position
(Appliance forced to the ignition power).
7.
Adjust the slow ignition using the orange screw
8.
At the end turn microswitch 3 to OFF position
9.
Turn microswitch 1 to OFF position (test mode OFF).
The LED is still orange - all adjustments have been
stored.
Close the hot water tap.
10. When the check is over, close the gas valve and tighten
screw "a", make sure it is securely in place
Open the gas valve and check the tightness of the screw.
WARNING
The settings of the maximum/minimum pressure and
the check of slow ignition must be made separately,
according to the instructions and completing the
procedure.
1
DIP
2
1. Adjusting screw maximum / minimum and Soft
ignition power
2. Microswitch