Ariston NUOS FS 200 Instrucciones de instalación y mantenimiento - Página 18
Navegue en línea o descargue pdf Instrucciones de instalación y mantenimiento para Calentador de agua Ariston NUOS FS 200. Ariston NUOS FS 200 44 páginas. External air source heat pump water heater
5.2 T
D
ECHNICAL
ATA
Description
Tank Rated Capacity
Footprint (minimum)
Height
Weight Empty
Weight Full
Minimum ceiling height required
Maximum Operating Pressure
Condensate Drain
Air Intake
Air Exhaust
Maximum Duct Static Loss *
Cylinder
- Tested in accordance with:-
Normal Operating Pressure
Maximum Water Supply Pressure
Cold Connection (feed)
Hot Connection (draw off)
Pressure Reducing Valve Set Pressure
Cylinder TPRV
Combination Valve PRV
Expansion Vessel Pre-Charge Pressure
Cylinder Indirect Coil
Connections
Surface Area
Maximum Supply Pressure
Rating @ 60°C
Primary Flow Rate
Pressure Drop through coil @15l/m
Heat Pump
Heat Rating**
Power Consumption**
COP** (see 1.7)
Heating Time**
Heating Energy Consumed**
Max. Water in Single Intake V40 @ 55°C
Max. Water in Single Intake V40 @ 62°C
Max. Water Temperature
Max. Current Consumption
Expansion Valve Operating Pressure
Refrigerant Fluid
Type of Fluid
Quantity
Practical Limit for Room Volume***
Max. Pressure of Circuit - low side
Max. Pressure of Condenser Coil
Max. Pressure of Circuit - high side
*Maximum permissible static loss for both supply air duct and exhaust air duct, when applicable.
**Values obtained with air temp. of 15°C and 37% relative humidity, input water temp. 15°C (in conformity to EN 255-3 specifications).
***The practical limit is the minimum room volume the appliance should be installed in, the volume is based on quantity of refrigerant in the
system. In the event of a sudden release of refrigerant then the minimum room volume will make it safer for the engineer.
18
FS 200
200 litre
0.6 x 0.6m
1.70m
90kg
290kg
1.75m
6 bar
½" BSP F
Ø150mm
Ø150mm
70Pa
BS6700
3.5 bar
12 bar
¾" BSP-22mm MI
¾" BSP-22mm MI
3.5 bar
90-95ºC / 7 bar
6 bar
3.5 bar
2.775 kW
0.75 kW
3.7
3h:10min.
2.2 kWh
260 litres
348 litres
55°C
3 amp
10-24 bar
R134a
1.28 kg
5.12m³
1.0 MPa
24 bar
2.5 MPa
FSi 250
250 litre
0.6 x 0.6m
1.96m
110kg
360kg
2m
6 bar
½" BSP F
Ø150mm
Ø150mm
70Pa
EN 12897:2006
3.5 bar
12 bar
¾" BSP-22mm MI
¾" BSP-22mm MI
3.5 bar
90-95ºC / 7bar
6 bar
3.5 bar
FSi 250 only
¾" BSP-22mm
0.65m²
6 bar
210.0 litres
15 l/min.
14 mbar
2.775 kW
0.75 kW
3.7
3h:40min.
2.7 kWh
325 litres
435 litres
55°C
3 amp
10-24 bar
R134a
1.28 kg
5.12m³
1.0 MPa
24 bar
2.5 MPa