Ariston SB35E-VN Manual - Página 5
Navegue en línea o descargue pdf Manual para Calentador de agua Ariston SB35E-VN. Ariston SB35E-VN 20 páginas. Electric instant water heater
INSTALLATION INSTRUCTION
Caution before
installation!
Install the
appliance
1. Installation must be carried out by qualified personnel and in compliance to
the local authority regulations.
2. This heater must be permanently connected to the direct main current supply.
The use of a plug and socket is not recommended.
3. For the correct size of wire conductor corresponding to different electrical
loading, please refer to table1.
4. This heater operates at a minimum water pressure of 30kPa and 20kPa for
without pump model and with pump model, respectively and at a maximum
water pressure of 380kPa.
5. This heater will not function if there is insufficient water flow to trigger the
flow switch.
6. The built-in ELCB will automatically cut off the power supply in case there
is a current leakage above 15mA. (ELCB model only.)
7. The thermostat will automatically cut off the power supply if it has sensed
an abnormal rise in showering water temperature. Only qualified technicians
are allowed to reset the thermal cut-out built inside the appliance.
8. To avoid accidentally scalding, user is advised to operate the heater under
a water pressure above 30kPa at the inlet.
1. Select a suitable position in the bathroom.
2. Remove the screw A-(fig. 2b) at the bottom of the unit and lift up the front
cover and then unhook the two parts. Be careful not to break
locate at the top of the front cover.
3. Mark the screw points of the heater base on the wall. The heater position
should be 1.5 meter from the bathroom floor.
4. Mark the screws points of the hanger beside the heater.
5. Use 6mm diameter drill and make the wall plug holes for heater and shower
accessory to 35mm depth.
6. Insert the wall plugs and mount the heater firmly in position with the screws
provided.
7. Mount the shower hanger firmly with two wall plugs and screws.
3