Aeotec ZWA041 Manual del usuario - Página 5

Navegue en línea o descargue pdf Manual del usuario para Accesorios Aeotec ZWA041. Aeotec ZWA041 9 páginas.

Aeotec ZWA041 Manual del usuario
18/06/2021
Triple-click the tamper switch on Door / Window Sensor 7 - this begins to blink five times
After completion of the inclusion, it lights up once before it goes out.
Close the cover
Note: Closing the cover is important! If the housing is not closed, the sensor is permanently awake. Only when the
cover is closed does the sensor change to the idle state.
Functions of Door / Window Sensor 7.
Open/Close/Tamper
Once installed the sensor will report "open" and "close" status changes to a central Z-Wave controller using notification
commands.
Open/Close utilizes Notification Report.
Tamper utilizes Notification Report.
https://help.aeotec.com/support/solutions/articles/6000230382-door-window-sensor-7-basic-user-guide-zwa011-zwa041-
Aeotec Door Window Sensor 7 Basic guide : Aeotec Help Desk
5/9