Ariston genus evo 30 CF Instrucciones de instalación y mantenimiento - Página 33

Navegue en línea o descargue pdf Instrucciones de instalación y mantenimiento para Caldera Ariston genus evo 30 CF. Ariston genus evo 30 CF 48 páginas. Wall-hung
También para Ariston genus evo 30 CF: Manual del usuario (16 páginas)

Ariston genus evo 30 CF Instrucciones de instalación y mantenimiento
descrizione
note
INSERIMENTO CODICE D'ACCESSO
ruotare l'encoder per selezionare 234 e premere il tasto OK
MENU COMPLETO
0 RETE
0. 2 RETE BUS
0. 2. 0 Rete Bus attuale
Indicazione dispositivi connessi via BUS
0. 4 DISPLAY
0. 4. 0 Zona da impostare da dispay da 1 a 3 (nr)
0. 4. 1
Temporizzazione backlight
0. 4. 2 Disattiva tasto
termoregolazione
2 PARAMETRI CALDAIA
2. 0 IMPOSTAZIONI GENERALI
2. 0. 0 Impostazione temperatura
sanitario
regolabile dati Tasti 2
2. 2 IMPOSTAZIONI GENERALI
2. 2. 0 Lenta Accensione
2.2.0 Livello Lenta Accensione
Valore massimo
Valore minimo
Vedi Tabella riepilogativa gas
2. 2. 2
< Non Disponibile >
2. 2. 4 Termoregolazione
E' possibile attivare la termoregolazione premento il
tasto AUTO
2. 2. 5 Ritardo partenza in
riscaldamento
2. 2. 6 Confi gurazione caldaie
convenzionali
RISERVATO AL SAT Solo in caso di sostituzione della scheda
elettronica
2. 2. 8 Versione Caldaia
NON MODIFICARE
RISERVATO AL SAT Solo in caso di sostituzione della scheda
elettronica
2. 2. 9 Settaggio potenza nominale
caldaia
RISERVATO AL SAT Solo in caso di sostituzione della scheda
elettronica
area tecnica
range
Caldaia
da 1 a 10 minuti o
24h
0 = Tasto AUTO
attivo
1 = Tasto AUTO
diasattivato
da 60 a 36 (°C)
da 0 a 100
0 %
100%
0%
0 = Assente
1 = Presente
0= Disabilitato
1= 10 secondi
2= 90 secondi
3= 210 secondi
da 0 a 5
0= Monotermica
camera aperta
da 0 a 5
description
notes
SERVICE CODE
222
Rotate encoder clockwise to select code 234 and press O
COMPLETE MENU
0 NETWORK
0. 2 BUS NETWORK
0. 2. 0 Network Presence
Indication of the devices connected via BUS.
0. 4 BOILER USER INTERFACE
0. 4. 0 Zone to be set by display
1
0. 4. 1 Backlight timing
0
0. 4. 2 Thermoregulation button
0
deactivation
2 BOILER PARAMETERS
2. 0 GENERAL
2. 0. 0 DHW Setpoint Temperature
45
Setting by DHW button 2
2. 2 BOILER GENERAL SETTINGS
2. 2. 0 Soft ignition
0
2.2.0 Soft ignition
Maximum value
Minimum value
see Table summarising changes
2. 2. 2 < Not Available >
2. 2. 4 Termoregulation
0
Termoregulation can be activated by pressing the
AUTO button.
2. 2. 5 Heating ignition delay
0
2. 2. 6 Conventional boilers confi g
0
ONLY FOR SERVICE - To be used only in substitution P.C.B.
2. 2. 8 Boiler version
- NOT TO MODIFY
0
ONLY FOR SERVICE - To be used only in substitution P.C.B.
2. 2. 9 Set boiler heat power
ONLY FOR SERVICE - To be used only in substitution P.C.B.
technical area
value
K
Boiler
from 1 to 3 (nr)
from 1 to 10
minutes or 24 hours
0 = Enabled AUTO
button
1= Disabled AUTO
button
from 36 to 60 (°C)
from 0 to 100
0 %
100%
0%
0 = Absent
1 = Present
0 = Deactivated
1 = 10 seconds
2 = 90 seconds
3 = 210 seconds
from 0 to 5
0= Mono Opern
Chamber
from 0 to 5
1
0
0
0
0
0
0
0
33