10. Remove the pipe from the pressure gauge and connect
screw "C" to the pressure outlet in order to seal off the
gas.
11. Carefully check the pressure outlets for gas leaks (valve
inlet and outlet).
IMPORTANT!
Whenever you disassemble and reassemble the gas
connections, always check for leaks using a soap and water
solution.
10
61.eps
Max Heating
Adjustment
VR015A.eps

Removing the spark generator

1. Disconnect ignition leads "T" by pulling upward
(F
. 1.27);
IG
2. Remove the screw "V" (F
3. Remove the spark generator (F
45.eps
43.eps
44.eps
. 1.28);
IG
. 1.29).
IG
T
F
. 1.27
IG
V
F
. 1.28
IG
F
. 1.29
IG
B063