Ariston microSYSTEM 10 RFFI Manual de instrucciones de instalación - Página 10
Navegue en línea o descargue pdf Manual de instrucciones de instalación para Caldera Ariston microSYSTEM 10 RFFI. Ariston microSYSTEM 10 RFFI 20 páginas. Type c boilers
También para Ariston microSYSTEM 10 RFFI: Manual del usuario (16 páginas), Instrucciones de mantenimiento (24 páginas)
Exhaust
Type
10 RFFI
Coaxial
C12 (xx)
C32 (xx)
Systems
C42 (xx)
ø 60/100
2.11 R
T
OOM
HERMOSTAT
C
ONNECTION
To connect a room thermostat and/or time clock, it is necessary
to:
1. - Open the control panel as indicated in section 4.3;
2.- Remove screws "A" and remove the inspection cover from
the reverse of the control panel;
3. - For the room-thermostat connect the thermostat switching
wires to the position 5 and 6 and remove the wire link (for
three-wire thermostats connect the neutral to terminal N);
4. - For the time clock connect the clock switching wires to the
positions 3 and 4 and connect the clock motor electrical
supply to the terminals marked L and N.
Note:
A frost thermostat is built-in to the appliance.
For connection to control systems with zone valves
for hot water cylinders see section 3.
2.12
E
D
LECTRICAL
Maximum
Restrictor
Extension
ø 44 mm
Exhaust/Air
L min = 0.5 m
L = 5 m
L max = 1 m
Legend:
IAGRAM
Colours:
Risk of Condensation Forming
Piping not insulated
ø 44
restrictor
NO restrictor
NONE
NONE
A
- On/Off Switch
B
- On/Off L.E.D.
C
- Heating Switch
D
- Heating L.E.D.
E
- Reset Button
F
- Ignition Failure (Lockout) L.E.D.
A01 - Pump Pressure Switch
A02 - Frost Thermostat
A03 - Modulator
A04 - Circulation Pump
A05 - Regulation Thermostat
A06 - External Control System
A07 - Time Clock Connector
A08 - External (Room) Thermostat
A09 - Air Pressure Switch
A10 - Fan
A11 - Overheat Thermostat
A12 - Spark Generator/Gas Valve Supply
A13 - Detection Electrode
Wh - White
Bl
- Blue
Gry - Grey
Brn - Brown
Blk
- Black
Rd
- Red
Grn/Yll - Yellow/Green
10
Piping insulated
ø 44
restrictor
NO restrictor
NONE
NONE
A
T
2.1
ABLE