If you're using a Z-Stick:
Action Button
1. If your Z-Stick is plugged into a gateway or a computer, unplug it.
2. Take your Z-Stick to your MultiSensor .
3. Press and hold the Action Button on your Z-Stick for 3 seconds and then release.
4. Press the Z-Wave Button on your MultiSensor .
5. If your MultiSensor has been successfully removed from your network, its LED will
Advanced functions.
blink when you press the Z-wave Button. If the removal was unsuccessful, the LED
will stay solid for a few seconds when you press the Z-wave Button.
Changing batteries.
6. Press the Action Button on the Z-Stick to take it out of removal mode.
Your MultiSensor has built in battery level detection. It will automatically report its
battery level to the associated control point throughout its life until the battery is fully
If you're using a Minimote:
drained and needs replacing. The battery status will often be displayed in the user
interface of the control point.
When used properly in an optimised Z-Wave network, your MultiSensor can be
powered by batteries for 12 months before battery replacement is necessary.
Recommendation: For networks which do not offer a method to display the battery
level of your MultiSensor, it is recommended that the sensor be tested occasionally
to ensure that the batteries still hold enough charge to operate. Batteries naturally
lose their charge over time.
Removing your MultiSensor from a Z-Wave network.
1. Take your Minimote to your MultiSensor.
Your MultiSensor can be removed from your Z-Wave network at any time. You'll
2. Press the Remove Button on your Minimote.
3. Press the Z-wave Button on your MultiSensor .
need to use your Z-Wave network's main controller to do this and the following
4. If your MultiSensor has been successfully removed from your network, its LED will
instructions tell you how to do this using Aeotec by Aeon Labs' Z-Stick and Minimote
controllers. If you are using other products as your main Z-Wave controller, please
blink when you press the Z-wave Button. If the removal was unsuccessful, the LED
refer to the part of their respective manuals that tells you how remove devices from
will stay solid for a few seconds when you press the Z-wave Button.
your network.
5. Press any button on your Minimote to take it out of removal mode.
Monitoring motion.
gateway, the data will be displayed within its interface. The specific Z-Wave
commands for the support of monitoring is the Multilevel Sensor Command Class
The MultiSensor can send Basic Set Command to association group 1, which
and Multi Channel Command Class. Automatic reports are sent to association group
is setup via the Association Command Class, when the Motion Sensor detects
1, which is setup via the Association Command Class. Please consult the controller's
movement to control the associated devices to "OPEN" state. After 4 minutes by
operation manual for specific instructions on setting your MultiSensor.
default, if the Motion Sensor is not triggered again, the MultiSensor will send Basic
Set Command to these devices to set them to their "CLOSE" state. However, if the
Setting automatic report flags.
Motion Sensor is triggered again in 4 minutes, the MultiSensor will reset the timing
Parameter 101-103 [4 byte decimal] can be configured through your gateway in case
and start timing again.
The 4 minutes delay time can be changed through the usage of Z-Wave command
the default settings of your MultiSensor are not what you desire.
built into Z-Wave certified control points. (The specific Z-Wave command supporting
Decimal
lag
this function is Configuration Command Class) Please consult the operation manual
for these control points for specific instructions on setting the MultiSensor.
128
Light Sensor
64
Humidity Sensor
32
Temperature Sensor
Adjusting the sensitivity of your MultiSensor .
1
Battery Sensor
Turn the Sensitivity Knob in a clockwise direction to increase sensitivity and counter-
The table above shows a decimal representation of all flags that can be set on
clockwise to decrease sensitivity.
parameter 101-103 to report specific data.
Example use of the report table.
For example, if you want to report only the temperature and light sensor you would
add 32 + 64 and set the sum (96) to parameter 101, 102, or 103.
As another example, if you want to report only the light sensor and battery, you would
add 1 + 128, then set the sum (129) to parameter 101, 102, or 103.
And if you want to report all of the sensors, you would add the whole table together
and set the sum (225) to parameter 101, 102, or 103.
Setting an automatic report interval.
Parameter 111-113 [4 byte decimal] can be configured through your gateway in case
the default settings of your MultiSensor are not what you desire.
Parameter 111 will set the interval for Group 1 (parameter 101), parameter 112 will
set the interval for Group 2 (parameter 102), and parameter 113 will set the interval
Monitoring temperature, humidity and luminance.
for Group 3 (parameter 103).
As an example, you have set parameter 101 to 225 which will report all of the
Your MultiSensor can report temperature, humidity, and luminance across a Z-Wave
sensors, and you want to report it every 1800 seconds. Set parameter 111 to 1800 to
network when requested. If this function is supported by a controller, generally a
accomplish this.
Waking up your Multisensor.
and maintenance of the Products in accordance with installation instructions and
the operating manual supplied to Customer. Warranty claims must be made by
If your MultiSensor is battery powered, you will need to ensure that it is active when
Customer in writing within thirty (30) days of the manifestation of a problem. Aeon
configuring it. To do this, press and hold its Z-Wave Button for 3 seconds and then
Labs' sole obligation under the foregoing warranty is, at Aeon Labs' option, to repair,
release it. Your MultiSensor's LED should now be solid to indicate that it is active.
replace or correct any such defect that was present at the time of delivery, or to
remove the Products and to refund the purchase price to Customer.
When you are done configuring or communicating with your MultiSensor, you can
The "Warranty Period" begins on the date the Products is delivered and continues for
put it back into sleep mode to conserve battery power. To do this, press and hold its
12 months.
Z-Wave button for 3 seconds and then release it. Your MultiSensor's LED should
Any repairs under this warranty must be conducted by an authorized Aeon Labs
now be off to indicate that it is asleep.
service representative and under Aeon Labs' RMA policy. Any repairs conducted by
unauthorized persons shall void this warranty.
Resetting your MultiSensor.
Excluded from the warranty are problems due to accidents, acts of God, civil or
military authority, civil disturbance, war, strikes, fires, other catastrophes, misuse,
misapplication, storage damage, negligence, electrical power problems, or
At some stage or your primary controller is missing or inoperable, you may also wish
modification to the Products or its components.
to reset all of your MultiSensor's settings to their factory defaults. To do this, press
and hold the Z-Wave Button for 20 seconds and then release it. Your MultiSensor
Aeon Labs does not authorize any person or party to assume or create for it any
will now be reset to its original settings, and the LED will stay solid for 2 seconds and
other obligation or liability in connection with the Products except as set forth herein.
then turn off as a confirmation.
Aeon Labs will pass on to Customer all manufacturers' Material warranties to the
extent that they are transferable, but will not independently warrant any Material.
Customer must prepay shipping and transportation charges for returned Products,
Technical specifications.
and insure the shipment or accept the risk of loss or damage during such shipment
and transportation. Aeon Labs will ship the repaired or replacement products to
Power Supply: USB DC 5V or battery power(4×AAA batteries).
Customer freight prepaid.
Operating Temperature: -10 to 60 .
C
C
Measured Temperature Range: -10 to 50 . Accuracy: ±1 .
C
C
C
Customer shall indemnify, defend, and hold Aeon Labs and Aeon Labs' affiliates,
shareholders, directors, officers, employees, contractors, agents and other
Humidity Range: 20% to 80%. Accuracy: ±5% (at 25 ).
C
representatives harmless from all demands, claims, actions, causes of action,
Lighting: 0 to 1000 LUX.
Motion Sensitivity: 3 to 5 meters.
proceedings, suits, assessments, losses, damages, liabilities, settlements,
Water Proofing: IP42.
judgments, fines, penalties, interest, costs and expenses (including fees and
Wireless Range: Up to 500 feet/150 metres outdoors.
disbursements of counsel) of every kind (i) based upon personal injury or death or
injury to property to the extent any of the foregoing is proximately caused either by a
defective product (including strict liability in tort) or by the negligent or willful acts or
omissions of Customer or its officers, employees, subcontractors or agents, and/or
6
Warranty.
(ii) arising from or relating to any actual or alleged infringement or misappropriation
of any patent, trademark, mask work, copyright, trade secret or any actual or alleged
Aeon Labs warrants to the original purchaser of Products that for the Warranty Period
violation of any other intellectual property rights arising from or in connection with the
(as defined below), the Products will be free from material defects in materials and
products, except to the extent that such infringement exists as a result of Aeon Labs'
workmanship. The foregoing warranty is subject to the proper installation, operation
manufacturing processes.
IN NO EVENT SHALL AEON LABS BE LIABLE FOR ANY INDIRECT, INCIDENTAL, PUNITIVE,
Reorient or relocate the receiving antenna.
SPECIAL OR CONSEQUENTIAL DAMAGES, OR DAMAGES FOR LOSS OF PROFITS, REVENUE,
Increase the separation between the equipment and receiver.
OR USE INCURRED BY CUSTOMER OR ANY THIRD PARTY, WHETHER IN AN ACTION IN
Connect the equipment into an outlet on a circuit different from that to which
CONTRACT, OR TORT, OR OTHERWISE EVEN IF ADVISED OF THE POSSIBILITY OF SUCH
the receiver is connected.
DAMAGES. AEON LABS' LIABILITY AND CUSTOMER'S EXCLUSIVE REMEDY FOR ANY CAUSE
Consul the dealer or an experienced radio/TV technician for help.
OF ACTION ARISING IN CONNECTION WITH THIS AGREEMENT OR THE SALE OR USE OF
THE PRODUCTS, WHETHER BASED ON NEGLIGENCE, STRICT LIABILITY, BREACH OF
WARRANTY, BREACH OF AGREEMENT, OR EQUITABLE PRINCIPLES, IS EXPRESSLY LIMITED
Warning
TO, AT AEON LABS' OPTION, REPLACEMENT OF, OR REPAYMENT OF THE PURCHASE PRICE
FOR THAT PORTION OF PRODUCTS WITH RESPECT TO WHICH DAMAGES ARE CLAIMED.
Do not dispose of electrical appliances as unsorted municipal waste, use
ALL CLAIMS OF ANY KIND ARISING IN CONNECTION WITH THIS AGREEMENT OR THE SALE
separate collection facilities.
OR USE OF PRODUCTS SHALL BE DEEMED WAIVED UNLESS MADE IN WRITING WITHIN
Contact your local government for information regarding the collection systems
THIRTY (30) DAYS FROM AEON LABS'S DELIVERY, OR THE DATE FIXED FOR DELIVERY IN
available.
THE EVENT OF NONDELIVERY.
THE INDEMNITY AND WARRANTY IN ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHER
Certifications (regional):
INDEMNITIES OR WARRANTIES, WHETHER EXPRESS OR IMPLIED, INCLUDING THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
FCC NOTICE (for USA)
THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE
Z-Wave and Z-Wave Plus are registered trademarks of Sigma Designs and its subsidiaries in the
CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT.SUCH MODIFICATIONS
COULD VOID THE USER'S AUTHORITY TO OPERATE THE EQUIPMENT.
United States and other countries
STORE INDOORS WHEN NOT IN USE. SUITABLE FOR DRY LOCATIONS. DO NOT IMMERSE IN
WATER. NOT FOR USE WHERE DIRECTLY EXPOSED TO WATER.
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions:
1
This device may not cause harmful interference, and
2
This device must accept any interference received, including interference that
may cause undesired operation. This equipment has been tested and found to
comply with the limits for a Class B digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used
in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur
in a particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the equipment
off and on, the user is encouraged to try to correct the interference by one or
more of the following measures: