Whirlpool AWM 8000-P Manual de servicio - Página 2

Navegue en línea o descargue pdf Manual de servicio para Lavadora Whirlpool AWM 8000-P. Whirlpool AWM 8000-P 20 páginas. Access

Whirlpool AWM 8000-P Manual de servicio
30.08.2002 / Page 2
Doc. No: 4812 712 17647
Technical data
Dimensions
Height
Width
Depth
Weight
Without package
With package
Main connection
Voltage
Frequency
Power consumption
Fuse rating
Drum
Volume
Wash spin
Ramp spin
Speed spinning max.
Capacity of dry laundry
Cotton/coloured laundry
Easy care
Daily
Delicate
Handwash
Wool
Pressostat for washing-machine
Level1
Switching point
Reset
Overflow
Switching point
Water column drum
(measured inside of the drum, rear position)
Level1
Switching point
Overflow
Switching point
AWM 8000-E,P ,GR
8570 077 18000
96.5
cm
68.6
cm
73.5
cm
108
kg
110
kg
230
V
50
Hz
2.3
kW
10
A
78
l
35/40
rpm
100
rpm
1400
rpm
8
kg
3.5
kg
3.5
kg
2.5
kg
2.0
kg
2.0
kg
60 ± 5
mmWc
40 ± 5
mmWc
280 ± 20
mmWc
43 - 55
mm
248 - 314
mm
Whirlpool Europe
Customer Service
Nominal current
Contacts:
11 - 12
11 - 14
11 - 16
Contactsystem:
11 - 12 - 14
11 - 16
Door lock
Nominal current:
contacts
4 - 5
6 - 7
8 - 9
Coil 1 - 2 and 2 - 3 :
Nominal voltage
Frequency
Resistance 1 - 2 (lock)
Resistance 2 - 3 (unlock)
Locking time
Unlocking time
(max.6 cyles)
Heating element
Kind of heating
Nominal voltage
Nominal power
Heat conductor
resistance R25
Resistance NTC:
0 ˚C
30˚C
40˚C
50˚C
60˚C
70˚C
95˚C
Inlet valve
Water temperature max.
Rated flow > 1 bar
Pressure range
Nominal voltage
Frequency
Starting voltage
< 6 bar
6 -10 bar
Nominal current
Nominal power
Nominal resistor (20˚C)
S E R V I C E
~ 3mA
24V DC
~ 3mA
24V DC
~ 3mA
24V DC
jump contacts
slow action contacts
16 A
230V
16 A
230V
0.1 A
230V
230
V
45 - 65
Hz
133 ± 10% Ω
140 ± 10% Ω
40 ± 10
ms
1
s
Tubular heating element
with NTC- Sensor
230
V
2050
W
22 - 28
35.9
kΩ
9.8
kΩ
6.6
kΩ
4.6
kΩ
3.2
kΩ
2.3
kΩ
1.1
kΩ
60
˚C
8
l/min
0.5 - 10
bar
220/240
V
50
Hz
160
V
170
V
35
mA
6
VA
3.4 - 4.5
kΩ