Whirlpool WED7500VW Manual de uso y mantenimiento - Página 9
Navegue en línea o descargue pdf Manual de uso y mantenimiento para Secadora Whirlpool WED7500VW. Whirlpool WED7500VW 20 páginas. Compact electric dryer with 11 cycles
También para Whirlpool WED7500VW: Manual de uso y mantenimiento (20 páginas), Especificaciones (8 páginas), Dimensiones e información de instalación (1 páginas), Manual de instrucciones (8 páginas), Instrucciones de instalación (2 páginas)
6. Replace strain relief (with power cord inserted) back into the
terminal block cover. Do not tighten strain relief nut.
A
B
C
D
A. Terminal block cover
B. Strain relief
C. Strain relief nut
D. Power cord
7. Now complete installation following instructions for your type
of electrical connection:
4-wire (recommended)
3-wire (if 4-wire is not available)
Electrical Connection Options
If your home has:
And you will be
connecting to:
4-wire receptacle
A UL listed,
(NEMA Type 14-30R)
120/240-volt
minimum,
30-amp, dryer
power supply
cord
4-wire direct
A fused
disconnect or
circuit breaker
box
5"
(12.7 cm)
3-wire receptacle
A UL listed,
(NEMA type 10-30R)
120/240-volt
minimum,
30-amp, dryer
power supply
cord
3-wire direct
A fused
disconnect or
circuit breaker
box
3 "
(8.9 cm)
4-wire connection: Power supply cord
1. Locate the neutral ground wire inside the dryer cabinet,
Go to section
2. Connect ground wire (green or bare) of power supply cord to
4-wire connection:
3. Connect neutral wire (white or center wire) of power supply
Power supply cord
4-wire connection:
Direct Wire
3-wire connection:
Power supply cord
4. Connect the other wires to outer terminal block screws.
3-wire connection:
5. Replace the terminal block cover on the back of the dryer.
Direct Wire
6. Tighten strain relief nut.
4-wire connection: Direct Wire
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer
can be moved if needed.
Strip 5" (12.7 cm) of outer covering from end of cable, leaving
bare ground wire at 5" (12.7 cm). Cut 1 " (3.8 cm) from
3 remaining wires. Strip insulation back 1" (2.5 cm). Shape ends
of wires into a hook shape.
B
A
D
C
A. 4-wire receptacle (NEMA type 14-30R)
B. 4-prong plug
C. Ground prong
D. Neutral prong
E. Spade terminals with upturned ends
F. Ring terminals
behind the external ground conductor screw. Remove this
wire.
A
A. Remove neutral ground wire.
external ground conductor screw. Tighten screw.
cord under center screw of the terminal block.
B
A
A. Neutral wire (white or center wire)
B. Center terminal block screw
C. External ground conductor screw
D. Ground wire (green or bare) of power supply cord
Tighten screws.
F
E
C
D
9