Whirlpool 3SWED5205SQ1 Manual de uso y mantenimiento - Página 12
Navegue en línea o descargue pdf Manual de uso y mantenimiento para Secadora Whirlpool 3SWED5205SQ1. Whirlpool 3SWED5205SQ1 24 páginas. Electronic dryer
6"
(152 mm)
Door Clearance
3
22
/
"
4
(1076 mm)
Minimum spacing for recessed area or closet
installation
The dimensions shown following are for the minimum spacing
allowed.
Additional spacing should be considered for ease of
■
installation and servicing.
Additional clearances might be required for wall, door, and
■
floor moldings.
Additional spacing of 1" (25 mm) on all sides of the dryer
■
is recommended to reduce noise transfer.
For closet installation, with a door, minimum ventilation
■
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings
are acceptable.
The dryer must be exhausted outdoors.
■
No other fuel-burning appliance may be installed in the same
■
closet as the dryer.
Companion appliance spacing should also be considered.
■
12
/
14
"
1
2
(368 mm)
28"
(711 mm)
Minimum Required Spacing
14"max.
(356 mm)
4"
(102 mm)
0"
(0 mm)
Recessed front view
*Additional spacing recommended
*Opening is the minimum for a closet door
Electrical Requirements
A two-wire plus separate ground wire, or a 3-wire, single-
■
phase 230-volt, 50-Hz, AC only, electrical supply is required
on a separate 15-amp circuit, fused on both sides of the line.
A time-delay fuse or circuit breaker is recommended.
It is the personal responsibility and obligation of the customer
■
to contact a qualified electrician to assure that the electrical
installation is adequate and is in conformance with all local
codes and ordinances.
If codes permit and a separate grounding wire is used, it is
■
recommended that a qualified electrician determine that the
grounding path is adequate.
3"
(76 mm)
48 in.
(310 cm
18"
18"
(457 mm)
(457 mm)
24 in.
(155 cm
3"
(76 mm)
1"
(25 mm)
Closet side
view
2
)
2
2
)
2