5.
Connect ground wire
F
Connect ground wire (F) (green or bare) of power supply cord
to external ground conductor screw (A). Tighten screw.
6.
Connect remaining wires
Connect remaining wires to outer terminal block screws.
Tighten screws. Finally, reinsert tab of terminal block cover into
slot of dryer rear panel. Secure cover with hold-down screw.
Now, go to Venting Requirements.
3-Wire Power Supply Cord Connection
IMPORTANT: Use where local codes permit connecting
cabinet-ground conductor to neutral wire.
B
A
C
A. 3-wire receptacle (NEMA type 10-30R)
B. 3-prong plug
C. Neutral prong
D. Spade terminals with upturned ends
E. 3/4" (19 mm) UL listed strain relief
F. Ring terminals
G. Neutral (white or center wire)
3.
Remove center screw
Remove center terminal block screw (B).
A
E
D
F
G
B
4.
Connect neutral wire
Connect neutral wire (white or center) (C) of power supply cord
to center terminal block screw (B). Tighten screw.
5.
Connect remaining wires
Connect remaining wires to outer terminal block screws.
Tighten screws. Finally, reinsert tab of terminal block cover into
slot of dryer rear panel. Secure cover with hold-down screw.
Now, go to Venting Requirements.
Direct Wire Connection
Direct wire strain relief
1.
Attach direct wire strain relief
Unscrew the removable conduit connector (A) and any screws
from a 3/4" (19 mm) UL listed strain relief (UL marking on strain
relief). Put the threaded section of the strain relief through the
hole (B) below the terminal block opening. Reaching inside the
terminal block opening, screw the removable conduit connector
onto the strain relief threads (C).
B
C
A
B
C
33