Whirlpool CSP2760TQ3 Manual de instrucciones de instalación - Página 5

Navegue en línea o descargue pdf Manual de instrucciones de instalación para Secadora Whirlpool CSP2760TQ3. Whirlpool CSP2760TQ3 36 páginas. Commercial stacked dryer gas (120-volt,60-hz)or electric (120/240-volt,60-hz)

INSTALLATION REQUIREMENTS
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Tools needed
=1 8" (20 cm) or 10" (25 cm)
=1 Level
pipe wrench
=1 5/16" open-end wrench
=1 8" (20 cm) or 10" (25 cm)
=1 Vent clamps
adjustable wrench
=1 Pipe-joint compound
II
Flat-blade screwdriver
resistant to LP gas
II
Phillips screwdriver
II
Caulk gun and caulk (for
II Adjustable wrench that
installing new exhaust vent)
opens to 1" (25 mm) or 1"
II
Pliers
(25 mm) hex-head socket
wrench
II
Putty knife
Parts supplied
Remove parts bag from dryer drum. Check that all parts were
included.
[]
10-32 x 5/16" serrated screws (4)
[]
Security cotter pins (2)
Explosion Hazard
Keep flammable materials
and vapors, such as
gasoline, away from dryer.
Do not install in a garage.
Failure to do so can result in death, explosion, or fire.
If installing a gas dryer:
IMPORTANT: Observe all governing codes and ordinances.
[]
Check code requirements: Some codes limit or do not permit
installation of clothes dryers in closets or sleeping quarters.
Contact your local building inspector.
[]
Make sure that lower edges of the cabinet, plus the back and
bottom sides of the dryer, are free of obstructions to permit
adequate clearance of air openings for combustion air. See
"Recessed Area Installation Instructions" below for minimum
spacing requirements.
NOTE:
[]
The dryer must not be installed in an area where it will be
exposed to water and/or weather.
[]
This dryer must not be installed in a closet with a door.
Recessed
Area Installation
Instructions
This dryer may be installed in a recessed area. Minimum
installation clearances can be found on the rear of the dryer.
The dryer must be exhausted outdoors.
Minimum Installation
Clearances
Back
Sides
Top
Front
IRecessedl 2in,
I
0in,
I 12in, I
--
I
(50 mm)
(0mm)
(300 mm)
2" (50mm)
--_ i_-
(300 mm)
let
j--
+
O"
(0 mm)
0" (0 mm)-_//
"_
__.1_1.,__1,
0" (0 mm)
Recessed
Recessed
side view
front view
Additional clearances for wall, door, and floor moldings may be required
or if external exhaust elbow is used.
5