Whirlpool Duet WED9150WW0 Manual de instrucciones de instalación - Página 4
Navegue en línea o descargue pdf Manual de instrucciones de instalación para Secadora Whirlpool Duet WED9150WW0. Whirlpool Duet WED9150WW0 16 páginas. 27" electric dryer
También para Whirlpool Duet WED9150WW0: Manual de uso y mantenimiento (25 páginas)
Explosion Hazard
Keep flammable
materials
and vapors, such as
gasoline, away from dryer.
Place dryer at least 18 inches (460 ram) above the floor
for a garage installation.
Failure to do so can result in death, explosion, or fire.
You will need:
[] A location allowing for proper exhaust installation. See
"Venting Requirements."
[] A separate 30 amp circuit.
[] If using power supply cord, a grounded electrical outlet
located within 2 ft. (610 mm) of either side of dryer. See
"Electrical Requirements."
[] Floor must support dryer weight of 200 Ibs. (90.7 kg). Also
consider weight of companion appliance.
[] Level floor with maximum slope of 1" (25 mm) under entire
dryer. If slope is greater than 1" (25 mm), install Extended
Dryer Feet Kit, Part Number 279810. If not level, clothes
may not tumble properly and automatic sensor cycles may
not operate correctly.
For each arrangement,
consider allowing more space for ease
of installation and servicing; spacing for companion appliances
and clearances for walls, doors, and floor moldings. Space
must be large enough to allow door to fully open. Add spacing
on all sides of dryer to reduce noise transfer. If a closet door
or Iouvered door is installed, top and bottom air openings
in door are required.
Closet installation (dryer only):
3"
(76 ram}
3 mm
(76 ram}
(25 ram)
_
48 in. 2
(310 cm 2}
24 in.2
(155 cm _)
4
Cabinet installation (dryer only):
Closet Installation (stacked washer and dryer):
51/2
H
(140 ram)
(25 mm)
76"
[1 930 rnm)
48 in.2
(310 cm 2)
24 in?
155cm 2)
Custom under counter
installation (dryer only):
(25 ram)
39" rnin.
(990 ram)
All dimensions show recommended
spacing allowed, with tested
spacing of 0" (0 mm) clearance on sides and rear. Closet door
ventilation openings show minimum spacing required.