Whirlpool WGD7990XG0 Manual de instrucciones de instalación - Página 11

Navegue en línea o descargue pdf Manual de instrucciones de instalación para Secadora Whirlpool WGD7990XG0. Whirlpool WGD7990XG0 32 páginas. Gas dryer
También para Whirlpool WGD7990XG0: Manual de instrucciones de instalación (32 páginas)

Whirlpool WGD7990XG0 Manual de instrucciones de instalación
Special
provisions
for mobile
home installations:
The exhaust vent must be securely fastened to a noncombustible
portion of the mobile home structure and must not terminate
beneath the mobile home. Terminate the exhaust vent outside.
Mobile Home Exhaust installation
Determine
vent path:
[] Select route that will provide straightest
and most direct
path outdoors.
[] Plan installation to use fewest number of elbows and turns.
[] When using elbows or making turns, allow as much room
as possible.
[] Bend vent gradually to avoid kinking.
[] Use as few 90 ° turns as possible.
Determine
vent
length
and elbows
needed
for best
drying
performance:
[] Use following Vent System Chart to determine type of vent
material and hood combinations
acceptable to use.
NOTE: Do not use vent runs longer than those specified
in Vent System Chart. Exhaust systems longer than those
specified will:
[] Shorten life of dryer.
[] Reduce performance,
resulting in longer drying times
and increased energy usage.
The Vent System Chart provides venting requirements that will
help achieve best drying performance.
NOTE: Bottom exhaust installation have a 90 ° turn inside the
dryer. To determine maximum exhaust length, add on 90 ° turn
to the chart.
Vent system
chart
Number
of
Type
Box/Iouvered
Angled
90 ° elbows
of vent
hoods
hoods
0
Rigid metal
64 ft. (20 m)
58 ft. (17.7 m)
1
Rigid metal
54 ft. (16.5 m)
48 ft. (14.6 m)
2
Rigid metal
44 ft. (13.4 m)
38 ft. (11.6 m)
3
Rigid metal
35 ft. (10.7 m)
29 ft. (8.8 m)
4
Rigid metal
27 ft. (8.2 m)
21 ft. (6.4 m)
INS% L
SYSTEM
. Install
exhaust
hood
rnin.
12" rain.
(305 ram)
Install exhaust hood and use caulking compound to seal
exterior wall opening around exhaust hood.
Vent must fit over the exhaust hood. Secure vent to exhaust
hood with 4" (102 mm) clamp. Run vent to dryer location using
straightest path possible. Avoid 90 ° turns. Use clamps to seal
all joints. Do not use duct tape, screws, or other fastening
devices that extend into interior of vent to secure vent,
because they can catch lint.
11