Whirlpool WGD94HEA Manual - Página 2

Navegue en línea o descargue pdf Manual para Secadora Whirlpool WGD94HEA. Whirlpool WGD94HEA 2 páginas. Electronic dryer
También para Whirlpool WGD94HEA: Manual de uso y mantenimiento (40 páginas), Manual de uso y mantenimiento (19 páginas)

Whirlpool WGD94HEA Manual

INSTALLATION REQUIREMENTS

GAS SUPPLY REQUIREMENTS

:
Gas supply
This dryer is equipped for use with Natural gas. Dryer can be converted to L.P. gas. When rigid pipe is used it should be 1/2" IPS. When
acceptable to the gas supplier and local codes, 3/8" approved tubing may be used for lengths under 20 ft (6.1 m). For lengths over 20 ft (6.1 m), larger
tubing should be used. Pipe-joint compounds resistant to the action of L.P. gas must be used. An individual manual shutoff valve must be installed
within 6 ft (1.8 m) of the dryer in accordance with the National Fuel Gas Code ANSI Z223.1.

ELECTRICAL REQUIREMENTS

A 120-volt, 60 Hz, AC-only, 15 or 20 amp fused electrical supply is required. A time-delay fuse or circuit breaker and a separate circuit
are recommended.
WATER (STEAM MODELS ONLY) REQUIREMENTS
The dryer must be connected to the cold water faucet using new inlet hoses. Do not use old hoses. Do not overtighten.
Damage to the coupling can result.

VENTING REQUIREMENTS

xhaust venting: Exhaust your dryer to the outside. 4" (102 mm)
E
diameter vent is required. Rigid or flexible metal exhaust vent
must be used. Do not use plastic or metal foil vet. Exhaust hood
must be at least 12" (305 mm) from the ground or any object that
may be in the path of the exhaust.
Exhaust hoods:
Recommended Styles:
Louvered Hood
Acceptable Style:
Angled Hood
Determine vent path:
Select route that will provide straightest and most direct
path outdoors.
Plan installation to use fewest number of elbows and
turns.
When using elbows or making turns, allow as much
room
as possible.
Bend vent gradually to avoid kinking.
Use as few 90° turns as possible.
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Box Hood
Determine vent length and elbows needed for best
drying performance:
Use the "Vent System Charts" on the next page to determine
type of vent material and hood combinations acceptable to
use.
NOTE: Do not use vent runs longer than those specified
in "Vent System Charts."
Exhaust systems longer than those specified will:
Shorten life of dryer.
Reduce performance, resulting in longer drying times
and increased energy usage.
Standard Vent System Chart
Number of
90° elbows
0
1
2
3
4
Long Vent System Chart*
Number of
90° elbows
0
1
2
3
4
* For Model WGD71HEW only; for all other models, refer to the
Standard Vent System Chart above. To find your model number,
refer to the model and serial number plate in the inner door well.
NOTE: For long vent systems, use of box/louvered hoods will
improve venting regardless of length.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Type
Angled
of vent
hoods
Rigid metal
64 ft. (20 m)
Rigid metal
54 ft. (16.5 m)
Rigid metal
44 ft. (13.4 m)
Rigid metal
35 ft. (10.7 m)
Rigid metal
27 ft. (8.2 m)
Type
Angled
of vent
hoods
Rigid metal
160 ft. (48.8 m)
Rigid metal
150 ft. (45.7 m)
Rigid metal
140 ft. (42.7 m)
Rigid metal
130 ft. (39.6 m)
Rigid metal
120 ft. (36.6 m)