Whirlpool WGDXXHEX Especificaciones
Navegue en línea o descargue pdf Especificaciones para Secadora Whirlpool WGDXXHEX. Whirlpool WGDXXHEX 1 páginas. Whirlpool gas dryer dimensions
También para Whirlpool WGDXXHEX: Dimensiones del producto (1 páginas)
PRODUCT MODEL NUMBERS
WGD94HEX, WGD95HEX,
WGD97HEX, WGDXXHEX
:
Gas supply
This dryer is equipped for use with Natural
gas. Dryer can be converted to L.P. gas. When rigid
pipe is used it should be 1/2" IPS. When acceptable
to the gas supplier and local codes, 3/8" approved
tubing may be used for lengths under 20 ft (6.1 m).
For lengths over 20 ft (6.1 m), larger tubing should be
used. Pipe-joint compounds resistant to the action of
L.P. gas must be used. An individual manual shutoff
valve must be installed within 6 ft (1.8 m) of the dryer
in accordance with the National Fuel Gas Code ANSI
Z223.1.
:
Electrical
A 120-volt, 60 Hz, AC-only, 15 or 20 amp
fused electrical supply is required. A time-delay fuse or
circuit breaker and a separate circuit are recommended.
:
Water (Steam models only)
The dryer must be
connected to the cold water faucet using new inlet
hoses. Do not use old hoses. Do not overtighten.
Damage to the coupling can result.
:
Exhaust venting
Exhaust your dryer to the outside.
4" (102 mm) diameter vent is required. Rigid or flexible
metal exhaust vent must be used. Do not use plastic
or metal foil vet. Exhaust hood must be at least
12" (305 mm) from the ground or any object that
may be in the path of the exhaust.
Hood styles: A & B are recommended.
B
4"
(102 mm)
A
4"
A. Louvered hood
(102 mm)
B. Box hood
4"
C. Angled hood (acceptable)
(102 mm)
The vent system chart provides venting requirments
that will help to achieve the best drying performance.
Vent system chart:
NOTE: Side and bottom exhaust installations have
a 90° turn inside the dryer. To determine maximum
exhaust length, add one 90° turn to the chart.
Number of
Type of
Box or
o
Louvered
90 turns
vent
or elbows
hoods
0
64 ft (20 m)
Rigid metal
1
Rigid metal
54 ft (16.5 m)
2
Rigid metal
44 ft (13.4 m)
3
Rigid metal
35 ft (10.7 m)
Rigid metal
4
27 ft (8.2 m)
Select the route that will provide the straightest and most
direct path outdoors. Plan the installation to use the fewest
number of elbows and turns. Use the fewest 90° turns
possible.
Do not use vent runs longer than specified in vent length
chart.
Determine the number of elbows you will need.
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Gas Dryer
Dryer dimensions
5
/
"*
3
4
(146 mm)
5
3
/
"*
4
(146 mm)
C
2½"
(64 mm)
5"
Angled
(127 mm)
hoods
58 ft (17.7 m)
48 ft (14.6 m)
38 ft (11.6 m)
29 ft (8.8 m)
21 ft (6.4 m)
1"
(25 mm)
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
OVERALL DIMENSIONS
6
/
"
1
4
(159 mm)
Gas
29
/
"*
7
8
(759 mm)
3
"*
1
/
2
(89 mm)
6
"*
1
/
8
(156 mm)
14
/
"
3
8
(365 mm)
25
3
/
"
4
(654 mm)
6
1
/
"
4
(159 mm)
Gas
29
7
/
"*
8
(759 mm)
3
/
"*
1
2
(89 mm)
6
/
"*
1
8
(156 mm)
14
/
"
3
8
(365 mm)
25
"
3
/
4
(654 mm)
6"
(152 mm)
3"
(76 mm)
48 in.
2
(310 cm
)
2
/
76
1
"*
4
(1936 mm)
24 in.
2
(155 cm
)
2
3"
(76 mm)
1"
(25 mm)
1"
(25 mm)
Cabinet, Closet and Undercounter dimensions
For closet installation, with a door, the minimum
ventilation openings in the top and bottom of the
39" min.
(990 mm)
door are required. Louvered doors with equivalent
air ventilation openings are acceptable.
1"
For cabinet installation, with a door, the minimum
(25 mm)
ventilation openings in the top are required.
50
7
/
"
8
(1292 mm)
31
1
/
"
8
(790 mm)
Left or
right side
exhaust
10
1
/
"
8
(257 mm)
7"
(178 mm)
14"
(356 mm)
5"
(127 mm)
1"
(25 mm)
1"
(25 mm)
(76 mm)
34" min.
(864 mm)
5"
(127 mm)
(76 mm)
1"
(25 mm)
1"
(25 mm)
Ref. W10057364
3
1
/
"
2
(89 mm)
3"
48 in.
2
(310 cm
)
2
24 in.
2
(155 cm
)
2
3"
10/10